PT-8110 Differential Probe (1400Vp-p, 100MHz)
|
model number |
PT-8110 |
| Bandwidth (-3dB) | DC-100MHz |
| Attenuation ratio | 1:100/1000 |
| inaccuracies | ±2% |
| Input Impedance | 两端之间:8MΩ//1pF
单端对地:4MΩ//2pF |
| rising time | 3.5ns |
| -Output (into 50KΩ load) | 7V |
| -Offset (typical) | <±5mV |
| Oscilloscope Input Impedance | 1MΩ |
| common-mode mutual exclusion ratio | 60Hz:>80dB; 100kHz:>50dB |
| Input Voltage | 140Vp-p@1/100 1400Vp-p@1/1000 |
| Input DC Voltage | 70V@1/100 700V@1/1000 |
| common-mode voltage (electronics) | 700V |
| peak voltage | 700V |
| dc voltage | 700V |
| RMS | 490 V |
| operating temperature | 0~50℃ |
| Operating humidity | 20~75%RH |
| weights | 400g |
| sizes |
186*84*38 mm |



Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.