Micsig high-frequency AC and DC current probe CP3008 up to 8MHz bandwidth, 50A/300A dual-range design, support the measurement of 300A continuous current and 500A peak current, accuracy up to 1%, resolution of up to 10mA, combined with a high signal-to-noise ratio and low noise characteristics, to achieve the high-frequency switching power supply, high-current equipment and other scenarios of accurate signal capture. Built-in demagnetization and one-key auto-zero function, equipped with overload protection alarm and jaw closure indicator to ensure operational safety and fast response. Standard BNC interface design, applicable to all brands of oscilloscopes.
Easy handling of high current measurements
Supports measurement of large currents up to 300Arms, accurately capturing AC signals.
(The picture on the left shows the measurement of a 300Arms high current signal)
Intelligent Assistance
Supports overload and clamp head locking indicator alarms
Excellent design
50A/300A dual range design for both low and high current testing
Supports one-touch zero calibration/demagnetization
Safety isolation protection: overcurrent protection design to meet industrial grade safety standards
Adopts standard BNC interface design, applicable to all brands of oscilloscopes
Application Areas
New Energy Vehicle Design
Switching Power Supply Design
Electrotechnical experiments
Semiconductor Device Design
Avionics design
Inverter / Transformer Design
Electronic ballast design
Industrial Control / Consumer Electronics Design
Engine drive unit design
Power Electronics and Power Drives Experiment Design
model number | CP3008 |
---|---|
bandwidths | DC~8MHz |
rising time |
≤ 50ns |
range (of scales or measuring equipment) | 50 Arms 300 Arms |
Accuracy (DC, 45-66Hz max. continuous current) | ±1% ±10mA (50A) ±1% ±100mA (300A) |
resolution (of a photo) | 10mA (50A) 100mA (300A) |
noises | <35mApp (50A) <300mApp (300A) |
procrastinate | 40ns |
Output sensitivity | 1V / 10A (50A, 10X attenuation) 1V / 100A (300A, 100X attenuation) |
Overcurrent alarm value | ≥ 50Apk (50A) ≥ 300ApK (300A) |
Power supply method | DC 12V Adapter |
Maximum working voltage | CAT II 600V CAT III 300V |
Maximum Floating Ground Voltage | CAT II 600V CAT III 300V |
Jaw Diameter | 20mm |
Oscilloscope Side Interface | Universal standard BNC connector, can be used with all brands of oscilloscopes |