Scope of Application
Stepper motors, etc.
Technical indicators
| model number | ZC5841B |
| Maximum number of accessible channels | 20 ways, divided into two groups, channel 1 to 10 for a group, channel 11 to 20 for another group, each group of test parameters can be set independently. Each channel voltage can be automatically corrected |
| operating mode | Cyclic and continuous mode; can be set through the forward time, forward stop, reverse time, reverse stop, the number of runs, the number of cycles, as well as the cycle time, nested cycle and other parameters to realize the chemical test.
Cloth in subdivision: full step, half step, 1/4 step, 1/8 cloth, 1/16 cloth, 1/32 cloth |
| Channel Management | Each group of channels can start, stop or continue the relevant test at any time. |
| Real-time monitoring function | 20-channel simultaneous monitoring, real-time display of the test progress bar, countdown times, voltage, current and status on the screen. |
| warning of malfunction | The 20 LEDs on the panel show the location of the faulty channel and the cause of the fault is displayed on the screen at the same time. |
| user interface | 7-inch color LCD display, touch screen + keyboard shortcut input, Chinese interface. |
| Test Voltage | 3.00V~12.00V; (0.01V step) |
| drive frequency | 1PPS ~10000PPS |
| infrared detection | 20-channel infrared detection, bidirectional mounting of lift motors, bidirectional infrared sensing |
| Failure to judge | Number of consecutive failures |
| data storage | Save data on USB flash drive |
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.