TH283X series is a new generation of low-budget cost, high-performance compact LCR digital bridge, using the latest technology and high-density circuit design, condensing the essence of large-scale LCR tester, compact and small. Eliminate the traditional mechanical power switch, using software to control the power switch. 0.05% basic accuracy and good test stability comparable to high-end models. Equipped with 4.3-inch LCD display and newly upgraded interface system, it is beautiful and easy to operate. The instrument provides rich interfaces and is compatible with standard SCPI commands, so it can be conveniently composed of various test systems to meet the various needs of inspection, production and scientific research.
A. High performance, small size (can test DC resistance R at the same time)DC)Functional Features
The large 4.3-inch LCD display shows both setup parameters and test results (DC resistance RDC can be tested and displayed at the same time), and the function keys corresponding to the display functions provide quicker operation. The instrument also provides a Measurement Display 2 function, which allows users to quickly sort and set up test products and display results.
B. Empty fixture judgment
This function can help the user to troubleshoot poor contact or short circuit of the test fixture. If this function is turned on, the instrument will automatically take the value after multiplying the nominal value by 0.05 as the lower limit and the value after multiplying the nominal value by 100 as the upper limit according to the nominal value in the Limit Setting page. Any value beyond this upper and lower limit is regarded as an open or short-circuit of the fixture, and the instrument will stop outputting the sorting result signal of the HANDLER, so as to prevent erroneous judgment results from being output.
C.Intelligent zero function
The TH2830 series offers two types of calibration. One is open and short circuit correction for all frequency points using the insertion method. The other is open, short and load correction for the currently set frequency points. 201 calibration points are available.
D. Multi-point list test
The List Scan function allows automatic scanning of up to 201 points of test frequency, test level or DC bias. By using this function, the user can quickly and clearly obtain the trend of the characteristics of the test object, and determine the suitability of the test object for the actual application.
E. Convenient and fast file sorting test function
The TH2830's built-in comparison function divides the component under test into up to 10 steps (BIN1 through BIN9 and BIN OUT). Nine pairs of primary parameter limits and one pair of secondary parameter limits can be set. The user can be presented with a visual display of the number of steps or counts, as well as an audible and visual alarm.
F.Rich interface function
The TH2830 series testers provide the user with a Handler interface, which is primarily used for the output of the instrument's sorting results. When the instrument is used in an automatic component sorting test system, this interface provides the contact signal with the system and the output signal of sorting results. The tester also provides RS232C, USB DEVICE, and GPIB (optional) interfaces for remote data communication. These interfaces are ideally suited to the requirements of automation applications on the market today.
Product Model | TH2830 | TH2832 | TH2832D | |||
demonstrate | 4.3 TFT LCD display 480 x 272 | |||||
readings | 6-digit readout resolution | |||||
Basic Measurement Accuracy
(see technical specifications for details) |
LCRZ | 0.05% | ||||
DCR | 0.1% | |||||
Test Signal Frequency | 50Hz - 100kHz | 20Hz - 200kHz ,
Step 10mHz |
20Hz - 300kHz ,
Step 10mHz |
|||
Signal source output impedance | 30Ω, 100Ω selectable | |||||
AC Test Signal Level | Voltage: 10mV - 2Vrms, Minimum Resolution: 10mV Accuracy: 10%x Set Voltage + 2mV | |||||
Current: 100μA - 20mArms, minimum resolution: 0.1mA | ||||||
RDC Test Signal Level | 1V | 5mV - 2V | ||||
DC bias voltage source | ------ | 0V - ± 5V Minimum Resolution: 0.5mV, Accuracy: 1%x Set Voltage +5mV | ||||
------ | 0mA - ±50mA Minimum resolution: 0.5μA | |||||
test parameter | L, C, R, |Z|, D, Q, |Y|, G, X, θd, θr, RDC, Vm, Im, ∆% | |||||
DCR Display Range | 0.00001 Ω-999.999MΩ | |||||
LCR parameter display range | |Z|,R,X | 0.00001Ω - 99.9999MΩ | ||||
|Y|, G, B | 0.00001μS - 99.9999S | |||||
C | 0.00001pF - 9.99999F | |||||
L | 0.00001μH - 99.9999kH | |||||
D | 0.00001 - 9.99999 | |||||
Q | 0.00001 - 99999.9 | |||||
θ(DEG) | -179.999º - 179.999º | |||||
θ(RAD) | -3.14159 - 3.14159 | |||||
Δ% | -999.999% - 999.999% | |||||
Measurement results display | Measurement display 1: test status and results; Measurement display 2: sorting status and results | |||||
List Scanning | 201 points, Scanning Parameters: Test Frequency, AC Voltage, AC Current, DC BIAS Voltage, DC BIAS Current | |||||
Graphic Scan Analysis | ------ | |||||
Measurement speed | Fast:12.5ms, Medium:83ms, Slow:167ms | |||||
equivalent circuit | Series, Parallel | |||||
Measurement range | Automatic, Hold | |||||
trigger method | Internal, Manual, External, Bus | |||||
Average number of times | 1 - 255 | |||||
zeroing function | Open Circuit, Short Circuit, Load | |||||
mathematical operation | Direct reading, ΔABS, Δ% | |||||
Trigger delay time setting | 0 - 999s, 1ms step | |||||
Comparator Functions | 10-position binning, BIN1 - BIN9, NG, AUX | |||||
stall counting function | ||||||
PASS, FAIL front panel display | ||||||
memory (unit) | Internal: 40 sets of instrument built-in test setup files.
USB memory: setup file, GIF image, CSV data file |
|||||
connector | control interface | HANDLER (TH2832D option) | ||||
communication interface | USB HOST, RS232C, RS485 (option), GPIB (option) | |||||
memory interface | USB DEVICE | |||||
Upper shelf volume (mm) | 215(W)x88(H)x335(D) | |||||
Outline volume (mm) | 235(W)x105(H)x360(D) | |||||
weights | 3.6kg | |||||
electricity supply | 220/110V | 24V (DC) |
■ 测试频率:20Hz-300kHz
■ Basic accuracy: 0.05%
■ 支持DC24V供电(TH2832D)
■ 6-digit readout resolution
■ L-RDC simultaneous display
■ 201-point list scanning function
■ 10-speed sorting, counting function, PASS/FAIL indication
■ Soft power switch
■ 4.3-inch TFT LCD display
■ Selectable operation interface in Chinese and English
■ High performance, small size, low cost
■ Storage space: Built-in: 40 sets of setting files
USB extension: setup files, CSV format records, GIF images
■ Passive Components.
Evaluation of impedance parameters of capacitors, inductors, cores, resistors, piezoelectric devices, transformers, chip assemblies and network components, etc.
■ Other components.
Impedance evaluation of printed circuit boards, relays, switches, cables, batteries, etc.
standard equipment | |||||
Accessory Name | model number | ||||
Boxed Four-Ended Insulated Locking Kelvin Test Leads | TH26011CS | ||||
fixture (machining) | TH26048A | ||||
short circuit board | TH26010 |
optional | |||||
Accessory Name | model number | ||||
Magnetic Ring Clamp (Piece Type) | TH26007A | ||||
Magnetic Ring Fixture | TH26008A | ||||
Patch Test Leads with Boxes | TH26009B | ||||
fixture (machining) | TH26047 | ||||
Test Fixture | TH26062 | ||||
Test Fixture | TH26063 | ||||
High Frequency Patch Fixture | TH26108C | ||||
Dielectric Test Fixture | TH26077 |