TH2281B UHF Digital Millivolt/Power Meter
TH2281B UHF Digital Millivolt/Power Meter
TH2281B UHF Digital Millivolt/Power Meter
TH2281B UHF Digital Millivolt/Power Meter
TH2281B UHF Digital Millivolt/Power Meter
TH2281B UHF Digital Millivolt/Power Meter

TH2281B UHF Digital Millivolt/Power Meter

■ Measurement frequency range: 9kHz-3000MHz (coaxial detector)

9kHz-1200MHz (probe)

■ Measured voltage range: 1mV-10V

■ Measured power range: -47dBm-33dBm, 20nW-2W (50Ω load)

■ Excellent frequency response and voltage standing wave coefficient (VSWR)

■ Measurement display function: clear VFD display with 4½-digit dual readout

Primary display shows one reading, secondary display scrolls to other readings

Absolute values: mV, V, W, dB, dBV, dBmV, dBμV, Vp-p

Relative values: dB, %, Max/Min, Comp

■ Auto range and manual range switching function.

■ With automatic zeroing function.

■ USB_DEV interface as standard, optional GPIB and RS232C interface

■ Software menu settings: Measurement dB, %, Max/Min, Comp reference value setting

Interface function setting: GPIB, RS232C

Category. Tags. , Brand.

Inquire about this product

■ TH2281 series UHF digital millivolt/power meter, its test frequency range covers 9kHz~3GHz, thus filling the blank of voltage measurement in the low frequency band to the microwave band measurement of the full range coverage. Its equipped coaxial detectors and probes are indispensable tools for RF and microwave laboratories, test departments, and maintenance departments, and are thus widely used in factories, research departments, troops and schools.

model number TH2281B
Input Configuration RF Probe, 50Ω Coaxial Tee, NJ Type 50Ω Standard Load (one)
connector USB_DEV interface as standard, optional GPIB and RS232C interface
Fundamental Accuracy ±2% of reading value
Input Impedance Probe input impedance ≥ 100kΩ at low frequency, insert 50Ω load coaxial tee to measure voltage and power.
Measured voltage and power ranges 3.8mV, 38mV, 380mV, 3.8V, 10V
-35dBm, -15dBm, 5dBm, 25dBm, 33dBm
overload voltage AC≤15Vrms DC≤50V
frequency response error 9kHz-200MHz ±( 4% of reading value + 0.5% of full scale) 200MHz-800MHz ±( 8% of reading value + 0.5% of full scale) 800MHz-1000MHz ±( 10% of reading value + 0.5% of full scale) 1000MHz-1000MHz 1200MHz ±(12% of reading value + 0.5% of full scale)
Standing Wave Coefficient (VSWR) 9kHz-200MHz 1.10 200MHz-800MHz 1.30 800MHz-1000MHz 1.35 1000MHz-1200MHz 1.44

■ Measurement frequency range: 9kHz-3000MHz (coaxial detector)

9kHz-1200MHz (probe)

■ Measured voltage range: 1mV-10V

■ Measured power range: -47dBm-33dBm, 20nW-2W (50Ω load)

■ Excellent frequency response and voltage standing wave coefficient (VSWR)

■ Measurement display function: clear VFD display with 4½-digit dual readout

Primary display shows one reading, secondary display scrolls to other readings

Absolute values: mV, V, W, dB, dBV, dBmV, dBμV, Vp-p

Relative values: dB, %, Max/Min, Comp

■ Auto range and manual range switching function.

■ With automatic zeroing function.

■ USB_DEV interface as standard, optional GPIB and RS232C interface

■ Software menu settings: Measurement dB, %, Max/Min, Comp reference value setting

Interface function setting: GPIB, RS232C

standard equipment
Accessory Name model number
RF probe TH19003
Coaxial Tee TH19005
50Ω coaxial load TH19006