● The maximum, minimum, and average values of U/I/P have been added to the measurement screen.
● For single-phase to three-phase 4-wire, maximum corresponds to 380V power supply line
● Maximum test voltage 780V, display range up to 1000V
:: Simultaneous measurement of 3 circuits is possible for single-phase 2-wire (when the same power supply system is used).
● Minimum 50.000 mA range, leakage current can also be measured (requires optional sensor).
● Use of SD card for long time storage
:: The setup navigation function facilitates accurate wiring (the wiring status is displayed on the screen in real time).
Note: The PW3360-30 main unit cannot be measured alone. Please purchase the optional clamp sensor separately according to different measurement requirements. An SD card is required for data acquisition.
Basic parameters
| Measuring Lines (Number of measurable circuits) |
50/60 Hz, single-phase 2-wire (1-circuit/2-circuit/3-circuit), single-phase 3-wire (1-circuit), three-phase 3-wire/three-phase 4-wire (1-circuit), current only |
|---|---|
| Measurement items | Voltage/current RMS, voltage/current fundamental, voltage/current fundamental phase angle, frequency, voltage waveform peak value (absolute), current waveform peak value (absolute) Active/reactive/apparent power, power factor (delayed, ahead) or shifted power factor (delayed, ahead) Active (consumption, generation)/reactive power (delayed, ahead), active (consumption, generation)/reactive power cumulative power (delayed, ahead), active (consumption, generation)/reactive power unit time power (delayed, ahead), power factor cumulative power Pulse Input |
| Voltage range | AC 600V |
| Current range | AC 500.00mA~5.0000kA (measurement range varies depending on the sensor used),. AC 50.000mA~5.0000A (leakage current only) |
| power range | 300.00 W~9.0000 MW (depending on the combination of voltage/circuit range and measurement line) |
| Basic precision | Voltage: ±0.3% rdg. ±0.1% f.s Current: ±0.3% rdg. ±0.1% f.s + current sensor accuracy Power: ±0.3% rdg. ±0.1% f.s + current sensor accuracy (power factor = 1) |
| Display update rate | Approx. 0.5s (when using SD card and memory, except for LAN and USB communication) |
| Data logging | Real-time saving to SD card/memory |
| Save Interval | 1 to 30 seconds, 1 to 60 minutes, 14 steps switching |
| Saving items | Measured value saving: average, average-max-min only Screen copy: BMP format (save at minimum 5-minute intervals) Waveform saving: binary format (minimum 1-minute intervals) |
| connector | SD card LAN 100BASE-TX: HTTP server function, use communication software to set up and download data USB2.0: Recognizes SD card and memory as removable storage devices when connected to a PC, setting and downloading data through communication software. Pulse output: When measuring the accumulated power, the pulse signal proportional to the active power is output, open collector insulation output. |
| functionality | Wiring confirmation, setup navigation, screen copy, clock, display hold, etc. |
| power supply | AC Adapter Z1006 (100V to 240V, 50/60Hz), 40VA (with AC adapter) Battery pack 9459: DC 7.2V, 3VA, charging time 6 hours 10 minutes with AC adapter connected, continuous use time 6h (with backlight OFF) |
| Volume and weight | 180 W × 100 H × 50 D mm, 550 g (without battery pack PW9002) 180 W × 100 H × 67.2 D mm, 830 g (with Battery Pack PW9002) |
| attachment (email) | Voltage cable L9438-53 × 1 (black, red, yellow, blue), AC adapter Z1006 × 1, USB connecting cable (0.9m) × 1, Instruction manual × 1, Measurement guide × 1, Colored solenoids (2 each of red, yellow, and blue to differentiate the color of the clamp sensor) × 1 set, Solenoids × 5 (for bundling the clamp sensor cable), and 1 APP application CD ( SF4000 GENNECT One ) |
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.