:: Highly secure, compact and lightweight
● Even if the voltage is incorrectly input in the resistance range, accidents due to incorrect interruption of the earth leakage circuit breaker and arcing can be prevented.
:: Easy to use with resistance range and power check function
:: Rugged design with 1m drop protection
● The test cable can be stored on the main unit for easy daily operation.
● DC V basic accuracy ±0.5%, AC V frequency characteristics 40 to 1kHz standard type
● Low-pass filters to remove harmonics (measurement of fundamental components of inverters)
● Wide operating temperature range: -10℃~65℃.
● Display with backlight, CAT IV 300 V, CAT III 600 V
※ Regarding the accuracy of the DMM, since the DMM has a variety of measurement functions and ranges, it is recorded as a representative value of basic accuracy. Please refer to the catalog PDF for the accuracy of each range.
Basic parameters
| dc voltage | 600.0 mV to 600.0 V, 4 ranges, basic accuracy: ±0.5 % rdg. ±5 dgt. |
|---|---|
| alternating current | 6.000 V to 600.0 V, 3 ranges, Frequency: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±1.0 % rdg. ±3 dgt. (RMS, crest factor 3 or less) |
| resistive | 600.0 Ω to 60.00 MΩ, 6 ranges, 6 levels of measurement. Basic accuracy: ±0.9 % rdg. ±5 dgt. |
| electrostatic capacitance | - |
| frequency | AC V measurement: 3 ranges from 99.99 Hz (5 Hz or more) to 9.999 kHz. Basic accuracy: ±0.1 % rdg. ±2 dgt. |
| conductivity check | Conductivity ON Threshold: 25 Ω or less (Beep), OFF threshold: 245 Ω or more, Response time: 0.5 ms or more |
| Diode Testing | - |
| Power test (50/60Hz) | AC80~600V detection |
| Other Functions | Leakage circuit breaker false interruption prevention function, filter, display value hold, relative value display, automatic power saving |
| demonstrate | 4-digit LCD, max. 6000 dgt., bar graph |
| Display update rate | 5 times/s (Static capacitance: 0.05 to 5 times/s depending on measured value, frequency: 1 to 2 times/s) |
| power supply | Alkaline battery No. 7 (LR03) × 1, continuous use time: 35h (when backlight is off) |
| Volume and weight | 72W × 149H × 38D mm, 190 g (with battery and case) |
| attachment (email) | Test Lead DT4911 ×1, Protective Case ×1, Instruction Manual ×1, Alkaline Battery No. 7 (LR03) ×1 |
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.