Ground Resistance Tester FT6041
Ground Resistance Tester FT6041
Ground Resistance Tester FT6041
Ground Resistance Tester FT6041

:: Supports the 4-electrode method with a wide range of measurement functions.
● MEC function allows measurements without disconnecting the grounding pole
● Dust and waterproof IP67, operating temperature -25°C ~ 65°C, drop proof
● The use of grounding grid assemblies eliminates the need to insert auxiliary grounding rods.
:: Reduced operating time, with a measurement time of only 6 seconds and easy setup and stowage of the test line
● Current clamps can be easily clamped whether in confined areas or measuring busbars (option)
● Supports wireless communication for transmitting measurements to a smartphone or tablet PC (when option Z3210 is installed)

:: Clamp sensors can be used for measurements (FT6041-91 set with 2 clamp sensors)

Basic parameters (accuracy guaranteed for 1 year)

※1: -25°C to 40°C (80% RH or less), 40°C to 45°C (60% RH or less), 45°C to 50°C (50% RH or less), 50°C to 55°C (40% RH or less), 55°C to 60°C (30% RH or less), 60°C to 65°C (25% RH or less). 25% RH or less)

※2: With 4 rechargeable NiMH batteries (23°C reference value)

Measurement items Ground resistance measurement (4-electrode method, 3-electrode method, 2-electrode method, MEC function, clamp type), Low resistance measurement (4-terminal method, 2-terminal method), Voltage to ground measurement, earth resistivity
Voltage measurement to ground 0 to 30.0 Vrms, Accuracy: ±2.3% rdg ±8 dgt (50/60 Hz), ±1.3% rdg ±4 dgt (DC)
functionality Charged warning display, automatic power saving, earth resistivity display (4-electrode method only), zero setting, auto hold, continuous measurement, wireless communication (when Z3210 is installed), buzzer, comparator, display switching, overvoltage to earth display (low resistance measurement)
Temperature range -25°C to 65°C, *1 (non-condensing)
Storage temperature and humidity range -25°C to 65°C, below 80% RH (non-condensing)
Dustproof, Waterproof IP65, IP67 (IEC 60529, EN 60529)
Applicable standards EN IEC 61010-2-030: 2021 (safety), EN 61326 (EMC), EN 61557-1,EN 61557-10, EN 61557-4 (low resistance), EN 61557-5 (earth resistivity meter)
power supply Ni-MH rechargeable batteries size 5 × 4 or Alkaline batteries size 5 (LR6) × 4
Number of measurements

(*2)

500 cycles (3-electrode method, Z3210 not installed), 400 cycles (3-electrode method, Z3210 installed, wireless communication)
Volume and weight Approx. 189W × 148H × 48D mm, approx. 765 g (including battery and case)
attachment (email) Auxiliary grounding rod L9840 (1 set of 2) × 2, Test lead L9841 × 1, Test lead L9845-31 × 1, Test lead L9845-33 × 1, Test lead L9845-52 × 1, Grounding mesh assembly L9846 × 2, Test lead L9787 × 1, Carrying case C0208 × 1, Carrying case C0209 × 1, Alkaline battery No. 5 (LR6) × 1 4, Instruction manual ×1

Ground resistance measurement (4-electrode method, 3-electrode method, 2-electrode method)

operating method Applied Voltage, Voltage and Current Measurement (Effective Resistance Measurement by Synchronous Detection)
Measurement range 3 Ω (0 to 3.000 Ω) 30 Ω (0 to 30.00 Ω) 300 Ω (30.0 Ω to 300.0 Ω) 300 Ω or more 3 k Ω or less (300 Ω to 3000 Ω) 3 k Ω or more 30 k Ω or less (3.00 k Ω to 30.00 k Ω) 30 k Ω or more 300 k Ω or less (30.0 k Ω to 300.0 k Ω)
accurate unspecified ±1.5% rdg ±6 dg ±1.5% rdg ±4 dgt
Permissible resistance of auxiliary earth electrode 5 kΩ 50 kΩ 100 kΩ
Allowable voltage to ground 30 V rms or 42.4 V peak

MEC function (4-electrode method + clamp meter, 3-electrode method + clamp meter)

Measurement method Applied Voltage, Voltage and Current Measurement (Effective Resistance Measurement by Synchronized Detection)
Measurement range 30 Ω (0.00 Ω to 30.00 Ω) 300 Ω (30.0 Ω to 300.0 Ω) 3000 Ω (300 Ω to 3000 Ω) 30.00 k Ω (3 k Ω ~ 30.00 k Ω)
accurate ±5% rdg ±6 dgt ±5% rdg ±3 dgt

Ground resistance measurement (clamp type)

Measurement method Applied Voltage, Voltage and Current Measurement (Effective Resistance Measurement by Synchronized Detection)
Measurement range 20 Ω (0.02 Ω to 20.00 Ω) 200 Ω (20.0 Ω to 200.0 Ω) 500 Ω (200 Ω to 500 Ω)
accurate ±7% rdg ±3 dgt ±35% rdg

Low Resistance Measurement

open circuit voltage 4.0 V to 6.9 V
measured current 200 mA or more
Measurement range 30 Ω (0.00 Ω to 30.00 Ω) 300 Ω (30.0 Ω to 300.0 Ω) 3000 Ω (300 Ω to 3000 Ω)
accurate ±3 dgt (0.00 Ω ~ 0.19 Ω) ±2% rdg ±2 dgt (0.20 Ω ~ 10.00 Ω) ±2% rdg ±2 dgt