DC Signal Source SS7012
DC Signal Source SS7012
DC Signal Source SS7012
DC Signal Source SS7012
DC Signal Source SS7012
DC Signal Source SS7012

DC Signal Source SS7012

Signal generation and measurement can be performed simultaneously
DC signal generator, signal generation and measurement simultaneously ±25 V, ±25 mA Thermocouple signals n, K, E, J, T, R,S, B, N Thermocouple DC Voltage DC Current Measurement Battery Powered

Category. Tag. Brand.

Inquire about this product

● Improved stability and cost reduction compared to HIOKI's previous products.
:: Loop testing for control signal systems (4 - 20 mA)
:: Inspection of temperature control equipment and power distribution
:: 8 different thermocouple signals can be generated
● Ideal for power equipment measurement and production equipment maintenance
● Can be used as an electronic load (25mA DC max.)

 

An AC adapter and/or rechargeable battery and charger are recommended.

 

  • 3c8fd5bf6f521b8ccdb66320be190a2b

    Accurate Output, Safe Measurement Field Calibrator

    Field calibrator with accurate generator unit for calibration and measurement unit insulated from the output Compact size for travel and maintenance service Voltage output: ±25.000 V Current output: ±25.000 mA Measuring range: ±28.000 V ,±28.000 mA

  • 4e950873c3f1abf41073c140a772b34f

    2-Wire Transmitter Sensor Testing with Output Monitor

    Use the SS7012 for the supply voltage of the shunt. Monitor the current through the output of the sensor and confirm the operation of the sensor.

  • fc568b68c60618bf0c4e6567a34a4340

    Motion test of shunts

    Use the SS7012 as a current output for the sensor section. Supports current sinking (inhalation) so that settings for many situations can be reproduced.

  • 25e2271d1ec75c997ddb4a96f4d0ec0e

    Calibration testing of thermometers

    Test signals of TC, CV, CC, and Rs (100Ω) can be generated, enabling easy calibration.

  • Example of product use

    Loop testing during spot checks of industrial control instrumentation systems
    Maintenance of building electrical equipment
    Maintenance and repair of machinery
    Desktop Compact Generator-Power Supply
    Confirmation of power supply and power consumption of small equipment
    Calibration of thermometers

[Functions occurring]

output method Bipolar reception and occurrence
Constant Voltage (CV) 2.5 V: 0 ~ ±2.5000 V (±0.03 % setting ± 300 μV, 100 μV resolution)
25 V: 0 ~ ±25.000 V (±0.03 % setting ±3 mV, 1 mV resolution)
Constant Current (CC) 25 mA: 0 ~ ±25.000 mA (±0.03 % of setting ± 3 μA, 1 μA resolution)
Thermocouple (TC: 0°C) K: at TC: 0 °C, -174.0 ~ 1372.0 °C (±0.05 % setting ±0.5 °C, 0.1 °C resolution), others: E, J, T, R, S, B, N optional
Thermocouple (TC: RJ) K: at TC: RJ, -174.0 ~ 1372.0 °C (±0.05 % setting ±1.0 °C, 0.1 °C resolution), others: E, J, T, R, S, B, N optional
Standard Resistance (Rs) 100 Ω (±0.2 Ω)
spontaneity Memory step data: 20, Interval time: 1 ~ 99 s ( CV, CC, TC mode)

[Measurement Function

input voltage 2.5 V: 0 ~ ±2.8000 V (±0.03 % rdg. ±300 μV, 100 μV resolution, 1 MΩ input resistance)
25 V: 0 ~ ±28.000 V (±0.03 % rdg. ±3 mV, 1 mV resolution, 1 MΩ input resistance)
amps 25 mA: 0 ~ ±28.000 mA (±0.03 % rdg. ±3 μA, 1 μA resolution, 25 Ω input resistance)
temp -25.0 ~ ±80.0 °C (±0.5 °C at 23 ±5 °C, 0.1 °C resolution, using RJ Sensor 9184)
sampling rate Approx . 1.67 times / sec.
additional functionality Zeroing, Over-range display, USB communication, Monitor
power supply (of an appliance etc) AC adapter 9445-02 (100 ~ 240 V AC 50/60 Hz, 9 VA), Ni-MH batteries (HR6) × 4, 6 VA, (full capacity 2500 mAh Ni-MH batteries: 170 minutes of continuous use), or #5 (LR6) alkaline batteries × 4, 6 VA
Volume and weight 104 mm W × 180 mm H × 58 mm D, 660 g (with No. 5 (LR6) alkaline batteries × 4)
attachment (email) Input cable 9168 × 1, Test lead 9170-10 × 1, Fuse × 1, No. 5 (LR6) alkaline battery × 4, Operation manual × 1
Expand More
DC Signal Source SS7012DC Signal Source SS7012

Click to enquire

Product consultation and purchase:18218718851

I already understand