12-bit ADC for clear waveform details
SDS3000X HD series oscilloscopes all adopt 12-bit high-resolution ADC with quantization level up to 4096, and the resolution can be increased to 16-bit in high-resolution mode (ERES), which, together with the vertical & horizontal zoom function, helps users observe the details of the waveforms in a more complete and clearer way. For example, when analyzing an LLC half-bridge converter circuit, it is necessary to observe the dead time between the drive signals of the upper and lower tubes through the waveform, and the details of the waveform restored by the 12-bit oscilloscope are much clearer than that of the 8-bit oscilloscope.

ENOB - Effective and True ADC Bits
When a high-speed ADC performs data acquisition, the signal-to-noise-to-distortion ratio of the actual ADC falls short of the desired performance that its nominal bits should achieve due to noise and distortion. In general, the higher the oscilloscope bandwidth, the higher its internal noise. This is because high-frequency noise enters the high-bandwidth oscilloscope. Since the ADC is only a part of the oscilloscope system and cannot be used independently, the ENOB index of the whole oscilloscope system will be more meaningful.SDS3000X HD is up to 8.3-8.6-bit, with smaller time error and frequency spuriousness, as well as lower broadband noise, which can effectively ensure the accuracy of measurement.


Rich Trigger Functions
SDS3000X HD series oscilloscopes provide a wealth of trigger types, including edge, interval, timeout, video, serial bus, area trigger, etc. Among them, area trigger is different from the traditional trigger, which can be applied to episodic signals whose parameter characteristics are still unclear, and the signal capture can be completed by creating and defining an area using only the mouse or touch. Bus trigger supports I2C, SPI, CAN, CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT and other buses, providing test solutions for embedded, automotive, computer and other serial buses.

Template testing for efficient evaluation of signal quality
The template test function is mainly used for signal quality assessment, which can monitor the failure rate of waveforms for a long time and locate the causes according to the faulty waveforms. There are two ways to set rules, one is to create rules by drawing polygonal templates in the oscilloscope, the other is to create rules by setting horizontal and vertical values according to the "Perfect Waveform", and then the oscilloscope conducts real-time testing of the waveforms, and it can count the number of times of testing, number of times of failures, and failure rate within the specified testing conditions, and it can also set the "Store Failure Frames", and the failed waveforms can be viewed in history mode. It is also possible to set "Store Failure Frames", and the failed waveforms can be viewed in history mode.


Power supply analysis to quickly get power supply parameters
SDS3000X HD can be equipped with optional power supply analysis function, together with Dingyang's voltage probes (e.g. DPB5000 series) and current probes (CP6000 series), it can quickly and accurately analyze 12 parameters of power supply such as power quality, current harmonics, inrush current, transient response, safe operating area (SOA) of the MSO tube, etc., for example, to improve the efficiency of the power supply by minimizing switching loss, assess device operating stability by Statistical power devices in all working conditions transient parameters exceed the probability of safe operating area to assess the device operating stability, through the input current harmonic analysis, to observe whether there are abnormal harmonics affecting power quality, etc., can improve the efficiency of power supply developers.

| model number | analog bandwidth | channel number | Maximum real-time sampling rate | Maximum waveform capture rate | Maximum storage depth | vertical resolution | prices |
|---|---|---|---|---|---|---|---|
| SDS3104X HD | 1 GHz | 4 + EXT | 4 GSa/s | 890,000 wfm/s | 400 Mpts/ch | 12-bit | ¥45,980 |
| SDS3054X HD | 500 MHz | 4 + EXT | 4 GSa/s | 890,000 wfm/s | 400 Mpts/ch | 12-bit | ¥35,880 |
| SDS3034X HD | 350 MHz | 4 + EXT | 4 GSa/s | 890,000 wfm/s | 400 Mpts/ch | 12-bit | ¥29,880 |
| Specification | |||
|---|---|---|---|
| bandwidths | 1 GHz, 500 MHz, 350 MHz | Trigger Type | Edge, Slope, Pulse Width, Window, Under Amplitude, Interval, Timeout, Code Pattern, Video, Premise Edge, Nth Edge, Delay, Build/Hold Time, Serial Trigger |
| real time sampling rate | 4 GSa/s (single/dual channel mode), 2 GSa/s (quad channel mode) | mathematical operation | 4-way |
| channel number | 4 + EXT | 4M points FFT spectrum analysis; addition, subtraction, multiplication, division, integration, differentiation, square root, averaging, ERES, absolute value, sign, equivalence, inverse, logarithmic, exponential, interpolation, maximum hold, minimum hold, digital filtering, and other time-domain operations; support for formula editor to achieve complex nested operations | |
| Storage depth | 400 Mpts/ch (single-channel mode), 200 Mpts/ch (dual-channel mode). | Serial Trigger and Decode | Standard: I2C, SPI, UART, CAN, LIN |
| 100 Mpts/ch (Quad mode) | Options: CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT, Manchester (decode only), ARINC429 (decode only) | ||
| Waveform capture rate | Normal mode: up to 200,000 wfm/s. | Data analysis and data processing tools | Search, Navigation, History, Template Test, Digital Multimeter, Baud Graph, Power Analysis (optional), Waveform Histogram, Counter |
| Sequence mode: up to 890,000 wfm/s | Signal generator (optional) | External single channel, maximum output frequency 50 MHz, sampling rate 125 MSa/s, waveform length 16 kpts | |
| connector | USB 3.0 Host x2, USB 2.0 Host x1, USB 3.0 Device, 10M/100M/1000M LAN, External Trigger Input, Auxiliary Output (TRIG OUT, PASS/FAIL) | extend one's head (out or into) | 500MHz passive probes, 1 set per channel |
| surveying | Over 50 parameter measurements with histogram, trend and trajectory statistics support | ||
| digital channel | 16 channels, 1 GSa/s sample rate, 100 Mpts/ch memory depth | ||
| screen (TV, computer or movie) | 10.1-inch capacitive touchscreen display, resolution 1024*600 | ||
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.