  • Quantity
    • -
    • +
  •    
Inquire about this product
  • 200VA AC Test Capacity
  • Conforms to the requirements of the IEC 61010-2-034 safety specification
  • 7″ LCD color display
  • True RMS Flow Measurement
  • Capacitive load test capability up to 47μF
  • Provide statistical analysis/scanning function
  • Adjustable rise/fall time
  • U disk storage function for test data
  • Provides rear panel output
  • Over-zero start operation
  • Interface: RS-232C, USB host/device, Signal I/O, GPIB (optional)

Safety testing with perfect insight

GPT-12000 Series 200VA Electrical Safety Analyzer

Alternating Current Withstand Voltage Test (ACW), Direct Current Withstand Voltage Test (DCW), Insulation Resistance Test (IR), Ground Bonding Impedance Test (GB)

The entire lineup offers 4 models

Safety testing must be safe

GPT-12000 series electrical safety analyzers provide up to AC 200VA output capacity and comply with IEC61010-2-034 standard (Safety requirements for electrical equipment for measurement/control and laboratory use I. Special requirements for insulation resistance measuring equipment and compressive strength testing equipment).

We provide safety regulations for testing various electronic/electrical products or components as required by IEC, EN, UL, CSA, GB, JIS, and others.

We emphasize the safety of the user during safety testing and provide safety locks, multiple remote control methods, and safe discharge.

Safety testing must emphasize accuracy

The GPT-12000 series electrical safety analyzers offer a wide range of voltage/current settings, providing higher measurement resolution.

Output settings/measurement ranges: AC withstand voltage test (AC 5kV/40mA max), DC withstand voltage test (DC 6kV/10mA max), insulation resistance test (DC 1200V/50GΩ max), grounding resistance test (AC 32A/650mΩ max), and grounding conductivity test (DC100mA/70Ω max).

Measurement Resolution (AC Withstanding Voltage: 1μA; DC Withstanding Voltage: 0.1μA; Insulation Resistance: 0.1MΩ; Ground Resistance: 0.1mΩ; Conductivity Test: 0.01Ω)

Safety testing must consider functionality

The entire GPT-12000 series offers voltage rise and fall time settings and large capacitance testing capability (up to 47uF).

The GPT-12000 series not only provides a display of test results, but also provides a curve scanning function between the test voltage/current and the test results, allowing the user to analyze the voltage/current situation during the test process, which is especially convenient for finding insulation breakdown situations.

Statistical analysis, multistep testing, data saving and more are available.

Safety Engineer: 0512-666171777-672

18913132806

 

More video sharing content.

Goodwell Safety Test Knowledge Sharing https://v.youku.com/v_show/id_XNDYxNDE1OTUzNg==.html

GPT-12000 Safety Tester PPT Introduction https://v.youku.com/v_show/id_XNDYyMTc5MjU2MA==.html

GPT-12000 Series Capacitive Load Test Demo https://v.youku.com/v_show/id_XNDYyMTc5MjU0OA==.html

GPT-12000 USB flash drive auto storage function https://v.youku.com/v_show/id_XNDYyMjAyODQxNg==.html

GPT-12000 Rear Panel Introduction https://v.youku.com/v_show/id_XNDYyMjAyOTIxNg==.html

GPT-12000 Curve Scanning Function https://v.youku.com/v_show/id_XNDYyMjAyOTY4MA==.html

GPT-12000 Front Panel Introductionhttps://v.youku.com/v_show/id_XNDYyMjAyOTQ2MA==.html

GPT-12000 Data Statistical Analysis Functionhttps://v.youku.com/v_show/id_XNDYyMjAyOTkxMg==.html

GPT-12000 Operation Video https://v.youku.com/v_show/id_XNDg4NDY0MzUwOA==.html

Quick Selection

model number Key Features Rear Panel Output quantitative (science) contiguity standard interface
GPT-12004 AC/DC/IR/GB 200VA USB/RS-232/I/O ports
GPT-12003 AC/DC/IR 200VA USB/RS-232/I/O ports
GPT-12002 AC/DC 200VA USB/RS-232/I/O ports
GPT-12001 AC 200VA USB/RS-232/I/O ports

 

Detailed specifications

This specification applies to the GPT-12000 energized for at least 30 minutes at 15℃~35℃.

General Information
demonstrate 7" LCD
stockpile 100 groups in manual mode; 100 groups in automatic mode
power supply AC 100V~240V ± 10%, 50Hz/60Hz
Size & Weight 380(W) x 148(H) x 454(D)mm /approx. 15kg
exchangesPressure resistance test
Output Voltage Range 0.050kV~ 5.000kV
Output Voltage Resolution 1V
Output Voltage Accuracy ± (1% of setting +5V) (no load)
Maximum rated load (Table1) 200VA (5kV/40mA) [GPT-12XXX]
Maximum rated current 40mA [GPT-12XXX]

0.001mA~10mA(0.05k≤V≤0.5kV)

0.001mA~40mA(0.5kV<V≤5kV)

Output Voltage Waveform simple harmonic vibration
frequency 50 Hz / 60 Hz
Rate of change of voltage ± (1% +5V)[Maximum rated load--no load]
Voltmeter Accuracy ± (1% of reading+ 5 V)
Current measurement range 0.001mA~40.00mA [GPT-12XXX]
Current Resolution 1uA (1uA~9.999mA)

10uA(10.00mA~40.00mA)

Current measurement accuracy ± (1.5% of reading+30uA)
Judgment accuracy ± (3% of setting+30uA)
Upper/lower limit judgment function Yes
ARC Detection Yes
Rise time control function Yes
RAMP TIME 0.1~999.9S
Down time control function Yes
RAMP DOWN Time 0.0~999.9S
TIMER (test time)² OFF, 0.3S~999.9S
GND ON/OFF
WAIT TIME 0.0~999.9S
1, It takes at least 0.3 seconds to reach the set voltage of 50V/10mA.
2, The timer will turn off only when the upper current is set below 30 mA.
direct current (D.C.)Withstanding Voltage Test (for GPT-12002/12003/12004)
Output Voltage Range 0.050kV~6.000kV¹
Output Voltage Resolution 1V
Output Voltage Accuracy ±(1% of setting +5V) With no load
Maximum rated load 50W (5kV/10mA) [GPT-12xxx]
Maximum rated current 10mA [GPT-12XXX]

0.001mA~2mA(0.05kV£V£0.5kV)

0.001mA~10mA(0.5kV<V£6kV)

Voltmeter Accuracy ± (1% of reading+ 5 V)
Voltage Resolution ± (1% +5V)[Maximum rated load ->no load]
Current measurement range 0.001mA-10.00mA
Current measurement resolution 0.1uA

0.1uA (0.1uA~999.9uA)

1uA (1uA~9.999mA)

10uA (10.00mA)

Current measurement accuracy ±(1.5% of reading+3uA) when I<1mA

±(1.5% of reading+30uA) when I≥1mA

Judgment accuracy ± (3% of setting+30uA)
Upper/lower limit judgment function Yes
ARC Detection Yes
Rise time control function Yes
RAMP TIME 0.1~999.9S
Down time control function Yes
RAMP DOWN Time 0.0~999.9S
TIMER OFF, 0.3S~999.9S
GND ON/OFF
waiting time 0.0~999.9S
Maximum capacitive load DC mode 1uF
¹ It takes at least 0.3 seconds to reach the set voltage of 50V/2mA.
Insulation resistance test (for 12003/12004)
output voltage 50V-1200V
Output Voltage Resolution 50V
Output Voltage Accuracy ±(1% of setting +5V) with no load
Resistance Measurement Range 0.1MΩ~50GΩ
Measurement voltage / Measurement range / Measurement accuracy
50V≤V≤450V

 

 

0.1MΩ~1MΩ 5% of reading + 3 count
1MΩ~50MΩ 5% of reading + 1 count
51MΩ~2GΩ 10% of reading + 1 count
500V≤V≤1200V

 

 

 

0.1MΩ~1MΩ 5% of reading + 3 count
1MΩ~500MΩ 5% of reading + 1 count
501MΩ~9.999GΩ 10% of reading + 1 count
10G~50GΩ 20% of reading + 1 count¹
test voltage Display Range
50V≤V≤100V 000.1MΩ~10.00GΩ
150V≤V≤450V 000.1MΩ~20.00GΩ
500V≤V≤1200V 000.1MΩ~50.00GΩ
Voltage regulation ± (1% +5V) [Maximum rated load ->no load
Voltmeter Accuracy ±(1% of reading +5V)
short-circuit current 10mA max.
Output Impedance 2kΩ
Upper/lower limit judgment function Yes
Rise time control function Yes
RAMP UP 0.1~999.9S
Down time control function Yes
RAMP DOWN (downtime) 0.0~999.9S
waiting time 0.0~999.9S
TIMER 0.3S~999.9S2
GND ON/OFF
Note: When the insulation resistance ground mode is turned on, the GND OFFSET action needs to be performed.

1When the insulation resistance grounding method is ON, a maximum of 30 Gohm can be guaranteed.

2 When the insulation resistance grounding mode is on, the test time starts from 0.5 seconds.

 

Ground impedance test (for GPT-12004)
Output Current Range 3.00A~32.00A
Output current accuracy ±(1% of setting+0.2A) when 3A≤I≤8A
±(1% of setting+0.05A) 8A < I ≤ 32A
Output current resolution 0.01A
test voltage Approximately max. 8VAC (open-circuit)
frequency 50Hz/60Hz selectable
Resistance Meter Measuring Range 1mΩ ~ 650mΩ
Resistance Meter Measurement Resolution 0.1mΩ
Resistance Meter Measurement Accuracy ±(1% of reading+2mΩ)
Resistance Meter Judgment Accuracy ±(1% of setting+2mΩ)
Upper and lower limit judgment function Yes
TIMER 0.3S~999.9S
GND ON/OFF

 

conductionbeta (software)
Output Current 100mA(DC)
Resistance Meter Measuring Range 0.10Ω~70.00Ω
Resistance Meter Measurement Resolution 0.01Ω
Resistance Meter Measurement Accuracy ±(10% of reading+2Ω)
Resistance Meter Judgment Accuracy ±(10% of setting+2Ω)
Upper and lower limit judgment function Yes
TIMER 0.3S~999.9S
connector
REMOTE (Remote Terminal) Yes
SIGNAL IO Yes
RS-232 Yes
USB (Device) Yes (USB 2.0)
Rear Output Yes
USB (Host) for data output port Yes (USB 2.0)
GPIB Yes (optional)

Standard Accessories
Quick Operation Manual x 1,
CD x1.
Power cord x 1,
Interlock key x 1,
Programmable Terminal Hookup GHT-119 x 1,
Test Lead GHT-115 x 1 for GPT-12003/12002/12001
Test Lead GHT-115 x 1, GTL-215 x 1 for GPT-12004

optional
Opt.1 GPIB card

Optional Accessories
GHT-113 High Pressure Test Gun
GHT-205 High Pressure Test Probe
GTL-232 RS232C Data Cable, 9-pin Female to 9-pin, null Modem for Computer
GTL-246 USB cable, A-B type, approx. 1.2m
GTL-248 GPIB cable, approx. 2m

 

GPT-12004 AC/DC/IR/GB Electrical Safety Analyzer

GPT-12003 AC/DC/IR Electrical Safety Analyzer

GPT-12002 AC/DC Electrical Safety Analyzer

GPT-12001 AC Electrical Safety Analyzer

Expand More
GPT-12000 Series Safety Tester 200VA Electrical Safety AnalyzerGPT-12000 Series Safety Tester 200VA Electrical Safety Analyzer
¥999,999.00
Purchase of goods

Product consultation and purchase:18218718851

I already understand