Restore voltage consistency to each cell through the charging and discharging process.
Chroma's Battery Module Balance Test System can detect the capacity and DC resistance of the battery cells to provide users with a basis for judgment, and then charge and discharge each string of cells to restore the voltage consistency of each string to restore the battery pack's power storage capacity and extend the battery pack's lifespan. Then, by charging and discharging each string of cells, the voltage consistency of each string can be restored to restore the power storage capacity of the battery pack and prolong the life of the battery pack.

Single Cell Capacity Test
A single cell is pulled and loaded at a constant current to discharge it, and a timer is started to calculate its usable capacity.

Single cell DC internal resistance test
Calculate the DC impedance (DCIR) using the voltage and current under the two loads.

Cell Balance Restoration
Through the control of charging and discharging, the voltage of each battery cell can be restored to the specified voltage level. The voltage and current of the object to be measured can be monitored at all times, and the protection voltage can also be set to link with the backend safety system.

Other customized functions, such as: MES system on-line statistical test data.
- Cell DC Impedance Measurement (DCIR)
- Single cell capacity test, detects individual cell capacity
- Cell balancing test to return the voltage of each cell to the specified voltage value
- Programmable test program with automatic execution
- Test conditions and results can be output in reports. Report formats can be developed
| model number | relate (a story or information) |
| 8700 | Battery Module Balancing Test System |
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.