High Voltage Differential Probes DP6000/A/B/D Series

High Voltage Differential Probes DP6000/A/B/D Series

¥999,999.00
  
  • Quantity
    • -
    • +
  •    
Inquire about this product

DP6000 Series High Voltage Differential ProbesIt is a high voltage differential probe with a floating ground measurement function. Its bandwidth is up to 70MHz, which meets the needs of most test systems. With abundant ranges to choose from, its differential measurement voltage range meets the requirements of most test circuits. If the probe is out of adjustment after long-term use, users can enter the test mode and adjust the bias to realize zeroing. Electronic light-touch keypad makes the service life longer. With 5MHz bandwidth limit function selection, 5MHz frequency bandwidth to meet most of the switching frequency measurement of FETs in the switching power supply, and can filter out higher frequency noise and interference. With sound and light alarm function, and can manually close the sound alarm function, more humanized design. usb power supply interface, more convenient and flexible use. The probe is equipped with a standard BNC output interface, can be used with any manufacturer's oscilloscope (the oscilloscope's input impedance is required to be set to 1MΩ; when selecting 50Ω, the attenuation multiplier will be more than double the attenuation) to measure the measured circuit waveform. Auto-save function prevents users from repeating the operation after power down. Probe with good common mode noise suppression, the input has a high input impedance and low capacitance, can accurately measure the differential voltage signal at high speed. Can be widely used in switching power supply, frequency converter, electronic ballasts, frequency conversion appliances and other electrical power devices, such as research and development, debugging or maintenance work.

DP6000ASeries High Voltage Differential ProbesIt is a high voltage differential probe with floating ground measurement function. Its bandwidth is up to 100MHz, which meets the needs of most test systems; abundant ranges are available, and its differential measurement voltage range meets the requirements of most test circuits; the user can enter the test mode to adjust the bias voltage, and if the probe is out of phase after long term use, the user can enter the mode to adjust the bias and realize zeroing; the electronic light-touch keypad makes the service life longer; it has a 5MHz bandwidth limit function selection, 5MHz frequency bandwidth to meet most of the switching frequency measurement of FETs in the switching power supply, and can filter out higher frequency noise and interference; with sound and light alarm function, and can be manually turned off the sound alarm function, a more humanized design; USB power supply interface, the use of more convenient and flexible; probe is equipped with a standard BNC output interface, and can be used in conjunction with any manufacturer's The probe is equipped with a standard BNC output connector, which can be used with any manufacturer's oscilloscope (the input impedance of the oscilloscope is required to be set to 1MΩ; when selecting 50Ω, the attenuation multiplier will be more than double the attenuation) to measure the waveform of the circuit under test; the auto-save function prevents users from repeating the operation after a power failure. Probe with good common mode noise suppression capability, the input has a high input impedance and low capacitance, can be accurate and high-speed measurement of differential voltage signals. Can be widely used in switching power supply, frequency converter, electronic ballasts, frequency conversion appliances and other electrical power devices, such as research and development, debugging or maintenance work.

DP6000BSeries High Voltage Differential ProbesIt is a high voltage differential probe with floating ground measurement function. Its bandwidth is up to 300MHz, which meets the needs of most test systems; abundant ranges are available, and its differential measurement voltage range meets the requirements of most test circuits; the user can enter the test mode to adjust the bias voltage, and if the probe is out of phase after long term use, the user can enter the mode to adjust the bias and realize zeroing; the electronic light-touch keypad makes the service life longer; it has a 5MHz bandwidth limit function selection, 5MHz frequency bandwidth to meet most of the switching frequency measurement of FETs in the switching power supply, and can filter out higher frequency noise and interference; with sound and light alarm function, and can be manually turned off the sound alarm function, a more humanized design; USB power supply interface, the use of more convenient and flexible; probe is equipped with a standard BNC output interface, and can be used in conjunction with any manufacturer's The probe is equipped with a standard BNC output connector, which can be used with any manufacturer's oscilloscope (the input impedance of the oscilloscope is required to be set to 1MΩ; when selecting 50Ω, the attenuation multiplier will be more than double the attenuation) to measure the waveform of the circuit under test; the auto-save function prevents users from repeating the operation after a power failure. Probe with good common mode noise suppression capability, the input has a high input impedance and low capacitance, can be accurate and high-speed measurement of differential voltage signals. Can be widely used in switching power supply, frequency converter, electronic ballasts, frequency conversion appliances and other electrical power devices, such as research and development, debugging or maintenance work.

DP6000DSeries High Voltage Differential ProbesIt is a high voltage differential probe with floating ground measurement function. Its bandwidth is up to 500MHz, which meets the needs of most test systems; abundant ranges are available, and its differential measurement voltage range meets the requirements of most test circuits; the user can enter the test mode to adjust the bias voltage, and if the probe is out of phase after long term use, the user can enter the mode to adjust the bias and realize zeroing; the electronic light-touch keypad makes the service life longer; and the 5MHz bandwidth limit function is selectable. 5MHz bandwidth limit function selection, 5MHz frequency bandwidth to meet most of the switching frequency measurement of FETs in the switching power supply, and can filter out higher frequency noise and interference; with sound and light alarm function, and can be manually turned off the sound alarm function, a more humanized design; USB power supply interface, the use of more convenient and flexible; probe is equipped with a standard BNC output interface, which can be used in conjunction with any manufacturer's The probe is equipped with a standard BNC output interface, which can be used with any manufacturer's oscilloscope (Requires the oscilloscope input impedance to be set to 50Ω (internal oscilloscope 50Ω is preferred)(math.) genus Alternatively, connect the standard through 50Ω load and set the oscilloscope input impedance to 1MΩ.)Measure the waveform of the circuit under test;Auto-save function prevents users from repeating the operation after power down. Probe with good common mode noise suppression ability, the input has a high input impedance and low capacitance, can accurately measure the differential voltage signal at high speed. Can be widely used in switching power supply, frequency converter, electronic ballasts, frequency conversion appliances and other electrical power devices, such as research and development, debugging or maintenance work.

DP6000 Electrical Specifications

Model No. DP6150 DP6350 DP6700
Bandwidth (-3dB) 70MHz
rising time ≤5ns
accurate ±2%
Range selection (attenuation ratio) 50X/500X 100X/1000X 100X/1000X
Maximum differential measurement voltage

(DC + Peak AC)

50X ±150V 100X ±350V 100X ±700V
500X ±1500V 1000X ±3500V 1000X ±7000V
Common mode voltage (DC + Peak AC) ±1500V ±3500V ±7000V
Maximum Differential Mode Voltage VS Frequency Curve Refer to Figure 1 Refer to Figure 2 Refer to Figure 3
Maximum input voltage to ground (Vrms) 600V CATIII

1000V CATII

600V CATIII

1000V CATII

1000V CATIII

2300V CATI

Input Impedance single-ended to ground (computing) 5MΩ 5MΩ 20MΩ
Two inputs 10MΩ 10MΩ 40MΩ
Input Capacitance single-ended to ground (computing) <4pF <4pF <5pF
Two inputs <2pF <2pF <2.5pF
CMRR DC >80dB >80dB >80dB
100kHz >60dB >60dB >60dB
1MHz >50dB >50dB >50dB
Noise (Vrms) 50X <50mV 100X <100mV 100X <220mV
500X <300mV 1000X <600mV 1000X <1.2V
Overload indication voltage threshold 50X 150V 100X 350V 100X 700V
500X 1500V 1000X 3500V 1000X 7000V
latency Probe host 50X 9ns 100X 9.3ns 100X 9.3ns
500X 7.5ns 1000X 7.4ns 1000X 7.2ns
BNC cable (1m) 5ns
Bandwidth Limit (5MHz) ≥-3dB@5MHz
Overload indicator (red) there are
Overload alarm sound Yes (optionally off)
Autosave Function there are
Adjustable bias function        Yes (enter test mode to adjust)
Terminal Load Requirements ≥100kΩ
power supply USB 5V/2A Adapter
Safety meets standards EN61010-1: 2010
EMC Compliance en61326-1:2013 en61000-3-2:2006+a1:2009+a2:2009 en61000-3-3:2013

 

DP6000A Electrical Specifications

Model No. DP6070A DP6150A DP6350A DP6700A
Bandwidth (-3dB) 100MHz
rising time ≤3.5ns
accurate ±2%
Range selection (attenuation ratio) 10X/100X 50X/500X 100X/1000X 100X/1000X
Maximum differential measurement voltage

(DC + Peak AC)

10X ±70V 50X ±150V 100X ±350V 100X ±700V
100X ±700V 500X ±1500V 1000X ±3500V 1000X ±7000V
Common mode voltage (DC + Peak AC) ±700V ±1500V ±3500V ±7000V
Maximum Differential Mode Voltage VS Frequency Curve Refer to Figure 1 Refer to Figure 2 Refer to Figure 3 Refer to Figure 4
Maximum input voltage to ground (Vrms) 450V CATII

600V CATI

600V CATIII

1000V CATII

600V CATIII

1000V CATII

1000V CATIII

2300V CATI

Input Impedance single-ended to ground (computing) 2.5MΩ 5MΩ 5MΩ 20MΩ
Two inputs 5MΩ 10MΩ 10MΩ 40MΩ
Input Capacitance single-ended to ground (computing) <4pF <4pF <4pF <5pF
Two inputs <2pF <2pF <2pF <2.5pF
CMRR DC >80dB >80dB >80dB >80dB
100kHz >60dB >60dB >60dB >60dB
1MHz >50dB >50dB >50dB >50dB
Noise (Vrms) 10X <25mV 50X <50mV 100X <100mV 100X <220mV
100X <120mV 500X <300mV 1000X <600mV 1000X <1.2V
Overload indication voltage threshold 10X 70V 50X 150V 100X 350V 100X 700V
100X 700V 500X 1500V 1000X 3500V 1000X 7000V
latency Probe host 10X 8.7ns 50X 8.5ns 100X 8.2ns 100X 8.9ns
100X 8.1ns 500X 7.5ns 1000X 7.4ns 1000X 6.6ns
BNC cable (1m) 5ns
Bandwidth Limit (5MHz) ≥-3dB@5MHz
Overload indicator (red) there are
Overload alarm sound Yes (optionally off)
Autosave Function there are
Adjustable bias function        Yes (enter test mode to adjust)
Terminal Load Requirements                      ≥100kΩ
power supply USB 5V/2A Adapter
Safety meets standards EN61010-1: 2010
EMC Compliance en61326-1:2013 en61000-3-2:2006+a1:2009+a2:2009 en61000-3-3:2013

DP6000B Electrical Specifications

Model No. DP6070B DP6150B DP6350B DP6700B
Bandwidth (-3dB) 300MHz
rising time ≤1.16ns
accurate ±2%
Range selection (attenuation ratio) 20X/200X 50X/500X 100X/1000X 200X/2000X
Maximum differential measurement voltage

(DC + Peak AC)

20X ±70V 50X ±150V 100X ±350V 200X ±700V
200X ±700V 500X ±1500V 1000X ±3500V 2000X ±7000V
Common mode voltage (DC + Peak AC) ±700V ±1500V ±3500V ±7000V
Maximum Differential Mode Voltage VS Frequency Curve Refer to Figure 1 Refer to Figure 2 Refer to Figure 3 Refer to Figure 4
Maximum input voltage to ground (Vrms) 450V CATII

600V CATI

600V CATIII

1000V CATII

600V CATIII

1000V CATII

1000V CATIII

2300V CATI

Input Impedance single-ended to ground (computing) 2.5MΩ 5MΩ 5MΩ 20MΩ
Two inputs 5MΩ 10MΩ 10MΩ 40MΩ
Input Capacitance single-ended to ground (computing) <4pF <4pF <4pF <5pF
Two inputs <2pF <2pF <2pF <2.5pF
CMRR DC >80dB >80dB >80dB >80dB
100kHz >60dB >60dB >60dB >60dB
1MHz >50dB >50dB >50dB >50dB
Noise (Vrms) 20X <90mV 50X <115mV 100X <350mV 200X <550mV
200X <120mV 500X <180mV 1000X <550mV 2000X <1V
Overload indication voltage threshold 20X 70V 50X 150V 100X 350V 200X 700V
200X 700V 500X 1500V 1000X 3500V 2000X 7000V
latency Probe host 20X 5.6ns 50X 5.5ns 100X 5.2ns 200X 5.1ns
200X 4.5ns 500X 4.5ns 1000X 4.2ns 2000X 4.2ns
BNC cable (1m) 5ns
Bandwidth Limit (5MHz) ≥-3dB@5MHz
Overload indicator (red) there are
Overload alarm sound Yes (optionally off)
Autosave Function there are
Adjustable bias function        Yes (enter test mode to adjust)
Terminal Load Requirements                        ≥100kΩ
power supply USB 5V/2A Adapter
Safety meets standards EN61010-1: 2010
EMC Compliance en61326-1:2013 en61000-3-2:2006+a1:2009+a2:2009 en61000-3-3:2013

 

DP6000D Electrical Specifications

Model No. DP6070D DP6150D DP6350D DP6700D
Bandwidth (-3dB) 500MHz
rising time ≤700ps
accurate ±2%
Range selection (attenuation ratio) 20X/200X 100X/1000X 200X/2000X 200X/2000X
Maximum differential measurement voltage

(DC + Peak AC)

20X ±70V 100X ±150V 200X ±350V 200X ±700V
200X ±700V 1000X ±1500V 2000X ±3500V 2000X ±7000V
Common mode voltage (DC + Peak AC) ±700V ±1500V ±3500V ±7000V
Maximum Differential Mode Voltage VS Frequency Curve Refer to Figure 1 Refer to Figure 2 Refer to Figure 3 Refer to Figure 4
Maximum input voltage to ground (Vrms) 450V CATII

600V CATI

600V CATIII

1000V CATII

600V CATIII

1000V CATII

1000V CATIII

2300V CATI

Input Impedance single-ended to ground (computing) 2.5MΩ 5MΩ 5MΩ 20MΩ
Two inputs 5MΩ 10MΩ 10MΩ 40MΩ
Input Capacitance single-ended to ground (computing) <4pF <4pF <4pF <5pF
Two inputs <2pF <2pF <2pF <2.5pF
CMRR DC >80dB >80dB >80dB >80dB
100kHz >60dB >60dB >60dB >60dB
1MHz >50dB >50dB >50dB >50dB
Noise (Vrms) 20X <90mV 100X <200mV 200X <350mV 200X <625mV
200X <130mV 1000X <420mV 2000X <730mV 2000X <1V
Overload indication voltage threshold 20X 70V 100X 150V 200X 350V 200X 700V
200X 700V 1000X 1500V 2000X 3500V 2000X 7000V
latency Probe host 20X 5.6ns 100X 5.5ns 200X 5.3ns 200X 5.6ns
200X 4.9ns 1000X 4.5ns 2000X 4.5ns 2000X 4.6ns
BNC cable (1m) 5ns
Bandwidth Limit (5MHz) ≥-3dB@5MHz
Overload indicator (red) there are
Overload alarm sound Yes (optionally off)
Autosave Function there are
Adjustable bias function        Yes (enter test mode to adjust)
Terminal Load Requirements                      50Ω 
power supply USB 5V/2A Adapter
Safety meets standards EN61010-1: 2010
EMC Compliance en61326-1:2013 en61000-3-2:2006+a1:2009+a2:2009 en61000-3-3:2013
Expand More
High Voltage Differential Probes DP6000/A/B/D SeriesHigh Voltage Differential Probes DP6000/A/B/D Series
¥999,999.00
Purchase of goods

Product consultation and purchase:18218718851

I already understand