*Fluke has implemented the global unified trademark management, Fluke 101/101 KIT/106/107 Chinese "FLUKE" trademark will be gradually transitioned to the English "FLUKE" trademark; at this stage, the Chinese trademark and the English trademark of these four models will coexist. At this stage, the Chinese and English trademarks of these four models will exist at the same time, and all of them are genuine FLUKE products, so please feel free to buy them.
Product Specifications: Fluke 106 Pocket Digital Multimeter
Accuracy applies for one year after calibration, at operating temperatures from 18 °C to 28 °C and relative humidity from 0 % to 75 % Accuracy specifications are in the format of ± ([% of reading] + [least significant digit])
Accuracy Specifications | ||||
functionality | range (of scales or measuring equipment) | resolution (of a photo) | accurate | |
alternating current1 | 6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
1.0 % + 3 | |
dc voltage | 6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V0.1 V |
0.5 % + 3 | |
AC millivolt | 600.0 mV | 0.1 mV | 3.0 % + 3 | |
resistive (Ohms) |
400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 |
|
capacitors2 | 50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000 μF |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
|
frequency 3 Hz (10 Hz - 100 kHz) |
50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
inapplicable | |
duty cycle3 | 1 % to 99 % | 0.10% | inapplicable | |
alternating current (electricity) (40 Hz - 200 Hz) |
4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | |
direct current | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | |
|
||||
functionality | overload protection | Input Impedance (nominal) | Common mode rejection ratio | Conventional mode rejection ratio |
alternating current | 600 V1 | >10 MΩ <100 pF2 | Under DC current. Greater than 60 dB at 50 Hz or 60 Hz |
- |
AC millivolt | 600 mV | >1M, <100 pF | Greater than 80 dB at 50 Hz or 60 Hz | - |
dc voltage | 600 V1 | >10 MΩ <100 pF | Under DC current. Greater than 100 dB at 50 Hz or 60 Hz |
Greater than 60 dB at 50 Hz or 60 Hz |
|
||||
General technical indicators | ||||
Maximum voltage applied to any terminal and to ground | 600 V | |||
Display (LCD) | 6000 counts, three updates per second | |||
Battery Type | Two AAA batteries (NEDA 24A, IEC LR03) | |||
Battery life | Minimum 200 hours | |||
temp | ||||
operating temperature | 0 °C to 40 °C | |||
Storage temperature | -30 °C to 60 °C | |||
relative humidity | ||||
Operating humidity | No condensation below 10°C ≤ 90 % at 10 °C to 30 °C; ≤ 75 % at 30 °C to 40 °C |
|||
Operating humidity, 40 MΩ range: | ≤ 80 % at 10 °C to 30 °C; ≤ 70 % at 30 °C to 40 °C | |||
height above sea level | ||||
Working altitude | 2000 m | |||
Storage altitude | 12000 m | |||
temperature coefficient | 0.1 X (specified accuracy)/°C (28 °C) | |||
Fuse protection for current input | 11A, 1000V Fast Fuse, Must Use Fluke Specified Parts | |||
Volume (H x W x L) | 142 mm x 69 mm x 28 mm | |||
weights | 200 g | |||
protection class | IEC 60529: IP 40 | |||
safety | IEC 61010-1: 600 V CAT III, pollution class 2 | |||
electromagnetic environment | IEC 61326-1: Portability | |||
electromagnetic compatibility | Applicable in Korea only. Class A equipment (industrial broadcasting and communications equipment)1 | |||
|