Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter

Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter

¥999,999.00

Main characteristics

  • For fast and safe testing of indoor/outdoor ground loop resistance, supports the use of unassisted pole measurements
  • AC Leakage Current Measurement: AC leakage current can be measured by not disconnecting the rod of the grounding system.
  • Rugged: heavy-duty jaws remain accurate and durable in harsh environments on site
  • Recording of measured values: up to 32,760 measured values in memory

SKU:Fluke 1630-2 Category. Brand.

  
  • Quantity
    • -
    • +
  •    
Inquire about this product

Product Overview: Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter

Tests the grounding resistance of equipment located in confined spaces (including indoors or in areas where auxiliary grounding electrodes are not permitted). Stay Connected - Identify ground loop resistance without having to disconnect the grounding electrode from the system and then reconnect it.

The Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter features the usual high quality and durability of Fluke tools. The durable clamp meter jaws ensure accuracy and durability even in industrial environments that run daily.

Unassisted Polar Measurement

The 1630-2/1630-2 FC Clamp Meter uses dual clamp jaws to measure ground loop resistance in multi-grounded systems. This testing technique eliminates the need to perform the dangerous and time-consuming task of disconnecting and connecting ground loops or finding a suitable location to install an auxiliary grounding electrode for testing. You can also perform grounding tests in locations that were previously difficult to maneuver: inside buildings, cable towers, or any location where there is no access to the soil to place an auxiliary grounding electrode.

6001319-FCLogo-RGB-240x72-3

Fluke Connect ® wireless system

The 1630-2/1630-2 FC supports the Fluke Connect wireless system (not available in all areas.) Fluke Connect connects wirelessly to the clamp meter using an app on your smartphone or tablet. The app displays ground resistance measurements on your smartphone or tablet screen. You can save these measurements, GPS locations from your phone, and images to Fluke Connect Cloud storage and share them with your team.

Product Specifications: Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter

Electrical specifications
Maximum ground voltage 1000 V
Battery Type AA alkaline IEC/EN LR6 (x4)
Battery life More than 15 hours*
* :: Backlighting and RF mode off in ground resistance measurement mode
frequency range 40 Hz to 1 kHz
protection class IEC/EN 60529: IP30 (jaws closed)
LCD Display digital reading 9999 counts
refresh rate 4/sec.
operating temperature -10 °C to + 50 °C
storage temperature -20 °C to + 60 °C
Operating humidity Non-condensing (<10 °C) (< 50 °F)
≤90% RH (at 10 °C to 30 °C [50 °F to 86 °F])
≤75% RH (at 30 °C to 40 °C [86 °F to 104 °F])
≤45% RH (at 40 °C to 50 °C [104 °F to 122 °F])
(non-condensing)
Working altitude 2000 m (6561 feet)
Storage altitude 12,000 m (39,370 feet)
reference temperature 23 °C ±5 °C (73 °F ±9 °F)
temperature coefficient 0.15% x (specified accuracy) / °C (28 °C [82.4 °F])
Overload indication OL
Data logging capacity Minimum 32,760 measured values
Data logging interval 1 second to 59 minutes and 59 seconds
Displays standard loop resistance reading specifications
Input (Ω) minimal greatest
0.474 0.417 0.531
0.5 0.443 0.558
="10" 9.55 10.45
="100" ="96" ="104"
safety
common (use) IEC/EN 61010-1: Level 2 contamination IEC/EN 61557-1
surveying IEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V
Current clamp meter for leakage current measurement IEC/EN 61557-13: Class 2, ≤ 30 A/m
earth resistance IEC/EN 61557-5
Effectiveness of protective measures IEC/EN 61557-16
Electromagnetic Compatibility (EMC) international standard IEC/EN 61326-1: Portable electromagnetic environments
CISPR 11: Group 1, Class B, IEC/EN 61326-2-2
Korea (KCC) Class A equipment (industrial broadcasting and communications equipment)
United States (FCC) 47 CFR 15 Subpart B. This product is considered tax-exempt equipment under Section 15.103.
radio
frequency range 2412 MHz to 2462 MHz
output power <10 mW
Radio frequency certification FCC ID:T68-FBLE IC:6627A-FBLE
General technical indicators
Conductor Specifications Approx. 40 mm (1.57 in)
Dimensions (L x W x H) 283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in)
weights 880g (31 oz)
warranty period 1 year
Ground loop resistance
range (of scales or measuring equipment) accurate ="1"  ± (± % + Ω of reading)
0.025 Ω to 0.249 Ω 1.5% + 0.02 Ω
0.250 Ω to 0.999 Ω 1.5% + 0.05 Ω
1.000 Ω to 9.999 Ω 1.5% + 0.10 Ω
10.00 Ω to 49.99 Ω 1.5% + 0.30 Ω
50.00 Ω to 99.99 Ω 1.5% + 0.50 Ω
100.0 Ω to 199.9 Ω 3.0% + 1.0 Ω
200.0 Ω to 399.9 Ω 5.0% + 5.0 Ω
400 Ω to 599 Ω 10.0% + 10 Ω
600 Ω to 1500 Ω 20.00%
="1" Loop resistance is non-inductive, conductors are centered and perpendicular to the jaws.
Ground leakage current measurement mA
Auto range 50/60 Hz, true RMS, crest factor CF ≤3
range (of scales or measuring equipment) resolution (of a photo) accurate ="1"  ± (± % + mA of reading)
0.200 mA to 3.999 mA 1 μA 2.0% + 0.05 mA
4.00 mA to 39.99 mA 10 μA 2.0% + 0.03 mA
40.0 mA to 399.9 mA 100 μA 2.0% + 0.3 mA
0.400 A to 3.999 A 1 mA 2.0% + 3 mA
4.00 A to 39.99 A 10 mA 2.0% + 30 mA
="1" Applicable signal frequency

  • 40 Hz to 1 kHz (with filter set to "Off")
  • 40 Hz to 70 Hz (when filter is set to "On")

Model: Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter

FLUKE-1630-2 FC
  • 1630-2 FC Ground Loop Resistance Test Clamp Meter
  • Hard suitcase
  • Standard Loop Resistance Calibration Board
  • 4 AA batteries
  • Safety Information Guide and Quick Reference Guide
Expand More
Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp MeterFluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
¥999,999.00
Purchase of goods

Product consultation and purchase:18218718851

I already understand