Fluke 1623-2 Ground Resistance Tester
Fluke 1623-2 Ground Resistance Tester
Fluke 1623-2 Ground Resistance Tester
Fluke 1623-2 Ground Resistance Tester
Fluke 1623-2 Ground Resistance Tester
Fluke 1623-2 Ground Resistance Tester
Fluke 1623-2 Ground Resistance Tester
Fluke 1623-2 Ground Resistance Tester

Fluke 1623-2 Ground Resistance Tester

¥999,999.00

Main characteristics

stakeless test

The Fluke 1623-2 Ground Resistance Tester measures ground loop resistance using only the jaws. To use this measurement method, two jaws are clamped to a ground rod and each jaw is connected to the tester. The use of a grounding stake is not required at all. One jaw senses a known fixed voltage and the other jaw measures the current. The tester then automatically determines the resistance of the earth rod. This test method is only applicable if the building or structure under test has a grounding system, although this is true in most cases. If there is only one pathway to ground, as is the case in many residential applications, and the stakeless test method does not provide an acceptable value, then the potential drop test method must be used.

With stakeless testing, there is no need to disconnect ground rods - the integrity of the bonded grounding system is maintained during the test. Now there's no need to spend time placing and connecting stakes to ground rods on the system, which can be a huge time saver. You can also perform grounding tests in locations you've never considered before, including inside buildings, cable towers, or anywhere you can't reach the ground.

Full-featured tester

The Fluke 1623-2 is a ground resistance tester with a difference, performing all four types of grounding measurements.

  • Three- and four-pole potential drops (using ground stakes)
  • Quadrupole soil resistivity test (using ground stakes)
  • Selective testing (using ground stake and 1 jaw)
  • Stakeless testing (using only 2 jaws)

SKU:Fluke 1623-2 Category. Brand.

  
  • Quantity
    • -
    • +
  •    
Inquire about this product

Product Overview: Fluke 1623-2 Ground Resistance Tester

The Fluke 1623-2 Ground Resistance Tester is capable of storing and downloading data via a USB port. Best-in-class accessories help simplify and speed up testing time.

  • Three-pole and four-pole potential drop ground resistance loop testing
  • Quadrupole soil resistivity test
  • Selective ground rod test using 1 jaw
  • Stakeless ground rod test using 2 jaws
  • IP56 protection for outdoor use
  • Hard Carrying Case
  • USB data storage and transfer

What's more, the tester is easy to use. With each test, the tester prompts you for the ground stake or jaws you need to use; a large rotary switch ensures that you can operate it even with gloves on.

Product Specification: Fluke 1623-2 Ground Resistance Tester

General technical indicators
Display: 1999-bit LCD Special symbol display, digit height 25 mm, fluorescent backlighting
user Instantaneous measurement is achieved by the one-button design of TURN and START. The only operating elements are the rotary switch and the START button.
Rugged, waterproof and dustproof Instrument designed for harsh environmental conditions (rubberized protective cover, IP56)
memory (unit) Access to up to 1500 records stored in internal memory via USB port
temperature range
operating temperature -10 °C to 50 °C (14 °F to 122 °F)
storage temperature -30 °C to 60 °C (-22 °F to 140 °F)
temperature coefficient ± 0.1% /°C of reading 28 °C
inherent error Please refer to the reference temperature range, one year guarantee
operating error Please refer to the operating temperature range, one year guarantee
climatic scale C1 (IEC 654-1), -5 °C to +45 °C (23 ° to +115 ° F), 5% to 95% RH
Type of protection Protection class IP56 for the housing and IP40 for the battery cover according to EN60529.
safety Protected by double and/or reinforced insulation. Max. 50 V to ground IEC61010-1: Pollution class 2
EMC (radiation immunity) IEC 61326-1: Portability
quality system Developed, designed and manufactured according to DIN ISO 9001 standards
External Voltage Maximum external voltage = 24 V (DC and AC < 400 Hz), measurement of higher values prohibited
External Voltage Rejection Ratio >120 dB (162/3, 50, 60 and 400 Hz)
measuring time Usually 6 seconds
Maximum overload 250 Vrms (which is a misuse)
auxiliary power 6 x 1.5 V alkaline batteries (AA LR6)
Battery life range Typically greater than 3000 measurements
Dimensions (W x H x D) 250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)
weights 1.1 kg (2.43 lb) with batteries
7.6 kg (16.8 lb) (in carrying case with accessories and battery)
RA Three-pole earth resistance measurement (IEC 1557-5)
Switching gears RA triple pole
resolution (of a photo) 0.001 Ω to 10 Ω
Measurement range 0.020 Ω to 19.99 kΩ
accurate ± (2% + 3 digits of reading)
operating error ± (5% + 3 digits of reading)
Measuring principle: current/voltage measurement
measured voltage Vm = 48 V (AC)
short-circuit current > 50 mA
Measurement frequency 128 Hz
Probe Resistance (R)S) 100 kΩ max.
Auxiliary grounding electrode resistance (RH) 100 kΩ max.
RH and RS The additional error of the RH[kΩ]---RS[kΩ]/RA[Ω]---0.2%
Use the error indicator to monitor RS and RHThe
Automatic range selection.
If the current through the current clamp is too low, no measurement will be performed.
RA Four-pole earth resistance measurement (IEC 1557-5)
Switching gears RA quadrupole (math.)
resolution (of a photo) 0.001 Ω to 10 Ω
Measurement range 0.020 Ω to 19.99 kΩ
accurate ± (2% + 3 digits of reading)
operating error ± (5% + 3 digits of reading)
Measuring principle: current/voltage measurement
measured voltage Vm = 48 V (AC)
short-circuit current > 50 mA
Measurement frequency 128 Hz
Probe Resistance (R)S + RES) 100 kΩ max.
Auxiliary grounding electrode resistance (RH) 100 kΩ max.
RH and RS The additional error of the RH[kΩ]---RS[kΩ]/RA[Ω]---0.2%
Use the error indicator to monitor RS and RHThe
Automatic range selection.
RA three-pole selective earth resistance measurement using current clamp (RA (using jaws)
Switching gears RA Three-pole, using jaws
resolution (of a photo) 0.001 Ω to 10 Ω
Measurement range 0.020 Ω to 19.99 kΩ
accurate ± (7% + 3 digits of reading)
operating error ± (10% + 5 digits of reading)
Measuring principle: current/voltage measurement (with external current clamp)
measured voltage Vm = 48 V (AC)
short-circuit current > 50 mA
Measurement frequency 128 Hz
Probe Resistance (R)S) 100 kΩ max.
Auxiliary grounding electrode resistance (RH) 100 kΩ max.
Use the error indicator to monitor RS and RHThe
Automatic range selection.
If the current through the current clamp is too low, no measurement will be performed.
RA four-pole selective ground resistance measurement using current clamp (RA (using jaws)
Switching gears RA Quadrupole, using jaws
resolution (of a photo) 0.001 Ω to 10 Ω
Measurement range 0.020 Ω to 19.99 kΩ
accurate ± (7% + 3 digits of reading)
operating error ± (10% + 5 digits of reading)
Measuring principle: current/voltage measurement (with external current clamp)
measured voltage Vm = 48 V (AC)
short-circuit current > 50 mA
Measurement frequency 128 Hz
Probe Resistance (R)S) 100 kΩ max.
Auxiliary grounding electrode resistance (RH) 100 kΩ max.
Use the error indicator to monitor RS and RHThe
Automatic range selection.
If the current through the current clamp is too low, no measurement will be performed.
Stakeless ground loop measurement (2 jaws)
Switching gears RA Quadrupole, 2 Jaws
resolution (of a photo) 0.001 Ω to 10 Ω
Measurement range 0.020 Ω to 19.99 kΩ
accurate ± (7% + 3 digits of reading)
operating error ± (10% + 5 digits of reading)
Measurement principle: stakeless measurement of the resistance in a closed loop using two current transformers
measured voltage Vm = 48 V (AC)
Measurement frequency 128 Hz
Noise Current (IEXT) Maximum IEXT = 10 A (AC) (R)A < 20 Ω)
Maximum IEXT = 2 A (AC) (R)A > 20 Ω)
Automatic range selection.
The information about the measurement of the stakeless ground loop is valid only if the measurement is carried out with the recommended current clamp at the specified minimum distance.

Model: Fluke 1623-2 Ground Resistance Tester

Fluke 1623-2
Fluke 1623-2 GEO Earth Ground Tester

Included:

  • GEO Ground Tester
  • user manual
  • batteries
  • Quick Reference Guide
  • 2 test leads
  • USB cable
Expand More
Fluke 1623-2 Ground Resistance TesterFluke 1623-2 Ground Resistance Tester
¥999,999.00
Purchase of goods

Product consultation and purchase:18218718851

I already understand