Product Overview: Fluke 802 Vibration Meter
802CN Vibration Meter "One Click Vibration Assessment of Mechanical Equipment"
Product Specification: Fluke 802 Vibration Meter
Built-in piezoelectric accelerometer | |
Sensitivity (typical) | 10.00 mV / m/s² ±5% (1 g = 9.8 m/s²) |
surveying | |
accelerations | |
range (of scales or measuring equipment) | 0.1 m/s² to 199.9 m/s² peak (rms √2) |
resolution (of a photo) | 0.1 m/s² |
accuracy | ± (5% + 2 digits) (LO: 10 Hz to 1 kHz) |
± (10% + 5 digits) (HI: 1 kHz to 10 kHz) | |
tempo | |
range (of scales or measuring equipment) | 0.1 mm/s to 199.9 mm/s rms |
resolution (of a photo) | 0.1 mm/s |
accuracy | ± (5% +2 digits) (10 Hz to 1 kHz) |
displacement (vector) | |
realm | 0.001 mm to 1.999 mm peak-to-peak (rms 2√2) |
power of resolution | 0.001 mm |
accuracy | ± (5% +2 digits) (10 Hz to 1 kHz) |
piezoelectric accelerometer | |
Typical frequency response | 10 Hz to 15 kHz |
unit of amplitude | |
accelerations | g, m/s2 |
tempo | mm/s |
displacement (vector) | mm |
Battery Type | 2 AAA, NEDA 24A, IEC LR03 |
External piezoelectric accelerometer | |
DC Bias Voltage | 6 V dc to 7 V dc |
DC Bias Current | 3.5 mA |
Note: Other technical specifications are the same as those of the built-in piezoelectric accelerometer. | |
Battery life | Measurement time 25 hours |
Dimensions (L x W x H) | 24.1 x 7.1 x 5.8 cm |
Weight .220 g | 220 g |
audio port (computer) | Stereo output jack (3.5 mm audio plug) |
External Sensor Port .M12 Plug | .M12 Plug |
matrix | |
operating temperature | -10 °C to 50 °C |
Storage temperature | -30 °C to 60 °C |
Operating humidity | 30% through 90% (non-condensing) |
Operating height | 2,000 m |
Storage height | 12,000 m |
IP rating | IP 40 |
Vibration limitation | 500.0 m/s² peak |
Drop test | 1 m |
electromagnetic compatibility | International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11 Group 1, Category A |
Group 1: Equipment generating and/or using conduction-related radio frequency energy internally, which is essential for the internal functioning of the equipment itself. Class A: Equipment intended for non-domestic use and in any installation not directly connected to the low voltage network supplying residential buildings. It may be difficult to ensure EMC in other environments due to conducted and radiated interference. This equipment, when connected to the test object, may produce emissions exceeding the levels specified in CISPR 11. |
Model: Fluke 802 Vibration Meter
Fluke 802CN
Fluke 802 Vibrometer