■ The new form-factor interface design and operation style are perfectly presented on the 4.3-inch TFT. This transformer test system provides 20Hz-200kHz test frequency, which meets the customer's measurement needs for switching transformers, network transformers and so on. The transformer scanning test covers a variety of low-voltage parameters of the transformer, and also provides a record and view of the number of times the relay of the scanning fixture has been used, so that the customer can have a comprehensive grasp of the status of the use of the relay and replace it in a timely manner.

Product Model TH2832XA Transformer Test Systems
Transformer test parameters Turn Ratio, Number of Turns, Phase, Inductance, Capacitance, Leakage Inductance, Quality Factor, AC Resistance, DC Resistance, Balance, Pin Short.
Fundamental Accuracy LCRZ 0.1%
DCR, Turn Ratio 0.5%
Test Signal Frequency 20Hz-200kHz Total 15025 points
Signal source output impedance 30Ω, 100Ω selectable
AC Test Signal Level normalcy 10mV-2Vrms Minimum resolution: 10mV, accuracy: 10%x set voltage +2mV
100μA-20mArms Minimum resolution: 0.1mA
constant level 20mV-1Vrms Minimum Resolution: 10mV, Accuracy: 10%x Set Voltage +2mV
200μA-10mArms Minimum resolution: 0.1mA
DC bias voltage source 0V-± 5V Minimum resolution: 0.5mV, Accuracy: 1%x set voltage +5mV
0mA-±50mA Minimum resolution: 0.5μA
LCR Digital Bridge Test Parameters |Z|,|Y|,C,L,X,B,R,G,D,Q,θ,DCR
DCR Display Range 0.00001Ω-999.999MΩ
Lap ratio display range 1:0.01-100:1
 

 

 

 

LCR parameter display range

|Z|,R,X 0.00001Ω-99.9999MΩ
|Y|,G,B 0.00001μs-99.9999s
C 0.00001pF-9.99999F
L 0.00001μH-99.9999kH
D 0.00001-9.99999
Q 0.00001-99999.9
θ(DEG) -179.999º-179.999º
θ(RAD) -3.14159-3.14159
Δ% -999.999%-999.999%
Measurement time (≥10 kHz) Fast: 25 times/second (40ms), Medium: 8 times/second (125ms) Slow: 2.7 times/second (370ms)
equivalent circuit Series, Parallel
Measurement range Automatic, Hold
trigger method Internal, Manual, External, Bus
Average number of times 1-255
zeroing function Open, Short, Load
mathematical operation Direct Reading,ΔABS,Δ%
Trigger delay time setting 0-60.000s,1ms steps
Step delay time setting 0-60.000s,1ms steps
 

Comparator Functions

10-speed binning, BIN1 to BIN9, NG, AUX
stall counting function
PASS, FAIL front panel or scanning fixture LED display
memory (unit) 100 sets of LCRZ instrument setting file memory 100 sets of transformer scanning setting file memory
connector control interface HANDLER or SCANNER
communication interface USB HOST, RS232C, RS485 (option), GPIB (option)
memory interface USBDEVICE
TH1831 Scanning Test Fixture Technical Parameters
Scan Test Output Pin 24Pin
24 Pin Scanning Output Distribution Capacitance 20pF
Transformer locking method (option) Pneumatic (TH1831-02) Maximum support 0.7MPa
Manual (TH1831-01)
Panel Test Control START, RESET button, PASS/FAIL LED indication
Handler interface (output from scanning fixture) Input/output signals Power supply: +5V, GND Input: START, RESET Output: PASS, FAIL On/off signal TTL level
External startup input Foot-activated switch
Operating Temperature, Humidity 0°C-40°C, ≤90%RH
Solenoid valve operating power output +24V
volumetric 228mm×203mm×53 mm
weights 2.9kg

■ 200kHz maximum frequency, independent LCR function

■ Built-in 0-50mA/0-5V bias power supply

■ Discrete Passive Component (L, R, C) Multi-Scan Testing

■ Multi-scan testing of relay driver packages, contact contact resistance

■ Multiple DC resistance DCR scan test

■ Comprehensive test analysis of multiple passive components in impedance networks

■ TH2832XA: LCR + Transformer Test System

TH2832XB: Transformer Test System

TH2832XC: Transformer Test System

■ 4.3-inch TFT LCD display with 272 x 480 resolution

■ New interface design

■ Switching transformer scanning tests, comprehensive characterization

■ Network transformer scanning tests, comprehensive characterization

■ Alternate DCR test signals

■ Provide single-parameter test cycles to test and judge individual windings

Adaptation of the TH1831 24Pin Transformer Scanning Fixture

■ Scanning fixture relay action count view, so that the customer on the status of the use of relay

grasp (often fig.)

■ Scanning fixture relay self-test function, to ensure the reliable operation of the scanning fixture

▪ Flexible deviation deductions

■ Parameter setting file compatible with TH2829X-24

■ Save test data or images in CSV, GIF format to USB memory.

■ The instrument can save 100 sets of setting files internally, and a large number of U disk setting files can be saved.

■ Support U disk software online upgrade mode

■ Provide PC-level instrument test setup file programming capability (optional)

■ RS-232, USB DEVICE and other interfaces to support host computer communication

Expand More
TH2832XA Automatic Transformer Test SystemTH2832XA Automatic Transformer Test System

Click to enquire

Product consultation and purchase:18218718851

I already understand