● In addition to current In addition to current, a variety of measurement items such as voltage, resistance, frequency, and power check can be measured.
● Simultaneous display of inrush current (INRUSH) RMS value and waveform peak value
Improved the strength of the jaws (current sensor section) for safer, long-term use.
● -25℃~65℃, wide range of applicable temperatures
● IP54 dust and water resistance ensures measurement function even when exposed to dust or water droplets
※The jaws (sensors) are IP50
● Prevents measurement errors by automatically determining AC and DC current/voltage.
● Beeps and red backlight alerts to danger when over-inputting
:: DC voltage up to 1700 V
Basic parameters (accuracy guaranteed for 1 year, adjusted accuracy guaranteed for 1 year)
| direct current | 20.00 A/600.0 A, basic accuracy: ±1.3% rdg. ±8 dgt. |
|---|---|
| alternating current (electricity) | 20.00 A/600.0 A, (10 Hz to 1 kHz, true RMS rectified) Basic accuracy: ±1.3% rdg. ±3 dgt. |
| dc voltage | 600.0 mV to 1500 V, 5 ranges, basic accuracy: ±0.5% rdg. ±3 dgt. |
| alternating current | 6.000 V to 1000 V, 4 ranges, (15 Hz to 1 kHz, true RMS rectification) Basic accuracy: ±0.9% rdg. ±3 dgt. |
| AC + DC current | 20.00 A/600.0 A, (10 Hz to 1 kHz, true RMS rectified) Basic accuracy: ±1.3% rdg. ±13 dgt. |
| AC + DC voltage | 6.000 V to 1000 V, 4 ranges, basic accuracy: ±1.0% rdg. ±7 dgt. |
| resistive | 600.0 Ω to 600.0 kΩ, 4 ranges, basic accuracy: ±0.7% rdg. ±5 dgt. |
| electrostatic capacitance | 1.000 μF to 1000 μF, 4 ranges, basic accuracy: ±1.9% rdg. ±5 dgt. |
| frequency | 9.999 Hz to 999.9 Hz, basic accuracy: ±0.1% rdg. ±1 dgt. |
| conductivity check | Conductivity ON Threshold: 25 Ω ±10 Ω (continuous beeping, warning backlight red) Conductivity OFF threshold: 245 Ω ±10 Ω, Response time: 0.5 ms or more |
| thyristor | Open circuit voltage: DC2.0 V or less, test current: 200 μA, clockwise: 0.15 V to 1.8 V |
| Temperature (K) | -40.0~400.0℃, Accuracy: ±0.5% rdg. ±3.0℃ + Temperature Probe Accuracy |
| a power test | Hi: AC40 V to 600 V, Lo: AC80 V to 600 V, 50/60 Hz |
| DC Power | Display range switching: 0.000 VA to 1020 kVA, accuracy: ±2.0% rdg. ±20 dgt. |
| crest factor | 20.00 A Range:7.5 600.0 A range: 500.0 A or less3, 500.0 A to 600.0 A or less2.5 |
| Other Functions | AC/DC auto judgment function, DC current/voltage positive/negative judgment function, maximum/minimum/average/peak maximum/peak minimum display, low-pass filtering function, display value hold, auto hold, backlight, auto power save, beeper |
| dustproof and waterproof | Hand-held part: IP54, jaws (current sensor part)/insulated part: IP50 |
| demonstrate | Display update rate 5 times/s (except electrostatic capacitance/frequency/temperature) |
| power supply | Alkaline 7 batteries (LR03) × 2, Continuous use time: 45 h (Backlight OFF) |
| Measurable conductor diameter | φ33 mm, Jaw size: 69 W × 14 D mm |
| Volume and weight | 65 W × 215 H × 35 D mm, 340 g |
| attachment (email) | Test Lead L9207-10 ×1, Carrying Case C0203 ×1, Alkaline Battery No. 7 (LR03) ×2, Instruction Manual ×1 |
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.