Main characteristics

  • 600 V Cat III Safety Design Index
  • Large display range out of 50% with bright white backlighting
  • Smart LED Test lights up the LED (regardless of polarity) and allows you to test the LED in two modes:
    •  DMM LED Socket Test Patterns
    •  LED test pattern on UUT (PCBA) (using test leads)
  • Voltage, resistance, current, capacitance
  • Diode Test, Data Hold
  • Frequency and Duty Cycle
  • AC and DC current measurements of 10A at the input terminals

SKU:Fluke 18B+ Category. Brand.

Inquire about this product

Product Overview: Fluke 18B+ Digital Multimeter

Fluke always provides you with superior quality.

Check and test most electronics problems with the Fluke 18B+ Digital Multimeter. The meter is easy to use and offers significant improvements over the original Fluke 18B. Ideal for anyone involved in electronics repair and manufacturing setups. Whether you've always wanted a Fluke digital multimeter or have been looking for a reason to upgrade, the Fluke 18B+ has you covered.

Product Specification: Fluke 18B+ Digital Multimeter

Accuracy Specifications

Calibrated to maintain accuracy for 1 year at operating temperatures from 18 °C to 28 °C and relative humidity from 0 % to 75 %. Accuracy specifications are in the form of ±([reading %] + [lowest significant digit]).

functionality range (of scales or measuring equipment) resolution (of a photo) accurate
alternating current 
(40 Hz to 500 Hz)1
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0 % + 3
dc voltage 4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5 % + 3
AC Voltage (mV) 400.0 mV 0.1 mV 3.0 % + 3
DC voltage (mV) 400.0 mV 0.1 mV 1.0 % + 10
Diode Testing2 2.000 V 0.001 V 10%
resistive 
(ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
capacitors3 40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
frequency1
Hz
(10 Hz - 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
0.1 % + 3
duty cycle1 1 % to 99 % 0.1 % 1 % Typical Situationl 4
AC Current μA
(40 Hz to 400 Hz)
400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3
AC current A
(40 Hz to 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC current μA 400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3
DC current mA 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3
DC current A 4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
1All current, frequency, and duty cycle ranges are from 1 % to 100 % of the range. input values below 1 % of the range are not specified.
2Typically, the open-circuit test voltage is 2.0 V and the short-circuit current <0.6 mA.
3Specifications do not include errors due to test lead capacitance and capacitor plates (up to 1.5 nF at a range of 40 nF).
4This usually means a frequency of 50 Hz or 60 Hz and a duty cycle between 10 % and 90 %.

 

functionality Luminous range Measurement range resolution (of a photo) accurate
LED VF Test 1 (LED test socket) 1.00 to 6.00 V NA NA NA
LED VF Test 2 (test leads) 1.00 to 6.00 V 1.00 to 6.00 V 0.01 V 10 % 3
Throughput Threshold inapplicable inapplicable inapplicable 70Ω
1 Open-circuit test voltage ±12 V, short-circuit current >±5 mA (typical)
2 Open-circuit test voltage ±12 V, short-circuit current >±3 mA (typical)
3 VF measurement with drive current below 2.2 ± 0.4 mA.

 

functionality overload protection Input Impedance (nominal) Common mode rejection ratio Conventional mode rejection ratio
alternating current 1000 V 1 >10 MΩ <100 pF Greater than 60 dB at 50 Hz or 60 Hz at DC current -
AC Voltage (mV) 400 mV >1MΩ, <100 pF Greater than 80 dB at 50 Hz or 60 Hz -
dc voltage 1000 V 1 >10 MΩ <100 pF Greater than 100 dB at 50 Hz or 60 Hz at DC current Greater than 60 dB at 50 Hz or 60 Hz
DC voltage (mV) 400 mV >1MΩ, <100 pF Greater than 80 dB at 50 Hz or 60 Hz -
1 106 V Hz max.

 

General technical indicators
Maximum voltage between any terminal and ground 1000 V
Display (LCD) 4000 counts, 3 updates per second
Battery Type 2 AA, NEDA 15A, IEC LR6
Battery usage time life 500 hours minimum (50 hours in LED test mode without load. Battery life with load depends on the type of LED being tested).
temp
operating temperature 0 °C to 40 °C
Storage temperature -30 °C to 60 °C
relative humidity
Operating humidity Non-condensing (<10°C) Less than or equal to 90% RH at 10 °C to 30 °C; less than or equal to 75% at 30 °C to 40 °C
40 MΩ range Less than or equal to 80% RH at 10 °C to 30 °C; less than or equal to 70% at 30 °C to 40 °C
height above sea level
operating temperature 2000 m
Storage temperature 12,000 m
temperature coefficient 0.1 X (specified accuracy) /°C (28 °C)
Fuse protection for current input 440 mA, 1000 V Fast Fuse, select Fluke parts only. 11A, 1000 V Fast Fuse, select Fluke parts only.
Volume (H x W x L) 183 x 91 x 49.5 mm
weights 455 g
IP rating IP 40
safety IEC 61010-1, IEC 61010-2-030 600 V CAT III, 1000 V CAT II, Pollution class 2
electromagnetic environment IEC 61326-1: Portability
electromagnetic compatibility Only available in Korea
Class A equipment (industrial broadcasting and communications equipment)1
1 This product meets the requirements for industry (Class A) EMP equipment and the salesman or user should be aware of this. This device is intended for commercial environments and is not suitable for home use.

Model: Fluke 18B+ Digital Multimeter

Fluke 18B+ Digital Multimeter

  • TL75 Test Leads with Two Caps
  • 2 x 5 batteries
  • user manual

Fluke 18B+ Digital Multimeter|Technical data [Please login to download and view].

15B+/17B+/18B+ | User's Manual [Please login to download and view].

Expand More
Fluke 18B+ Digital MultimeterFluke 18B+ Digital Multimeter

Click to enquire

Product consultation and purchase:18218718851

I already understand