Product Overview: Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
Tests the grounding resistance of equipment located in confined spaces (including indoors or in areas where auxiliary grounding electrodes are not permitted). Stay Connected - Identify ground loop resistance without having to disconnect the grounding electrode from the system and then reconnect it.
The Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter features the usual high quality and durability of Fluke tools. The durable clamp meter jaws ensure accuracy and durability even in industrial environments that run daily.
Unassisted Polar Measurement
The 1630-2/1630-2 FC Clamp Meter uses dual clamp jaws to measure ground loop resistance in multi-grounded systems. This testing technique eliminates the need to perform the dangerous and time-consuming task of disconnecting and connecting ground loops or finding a suitable location to install an auxiliary grounding electrode for testing. You can also perform grounding tests in locations that were previously difficult to maneuver: inside buildings, cable towers, or any location where there is no access to the soil to place an auxiliary grounding electrode.

Fluke Connect ® wireless system
The 1630-2/1630-2 FC supports the Fluke Connect wireless system (not available in all areas.) Fluke Connect connects wirelessly to the clamp meter using an app on your smartphone or tablet. The app displays ground resistance measurements on your smartphone or tablet screen. You can save these measurements, GPS locations from your phone, and images to Fluke Connect Cloud storage and share them with your team.
Product Specifications: Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
| Electrical specifications | ||
| Maximum ground voltage | 1000 V | |
| Battery Type | AA alkaline IEC/EN LR6 (x4) | |
| Battery life | More than 15 hours* | |
| * :: Backlighting and RF mode off in ground resistance measurement mode | ||
| frequency range | 40 Hz to 1 kHz | |
| protection class | IEC/EN 60529: IP30 (jaws closed) | |
| LCD Display | digital reading | 9999 counts |
| refresh rate | 4/sec. | |
| operating temperature | -10 °C to + 50 °C | |
| storage temperature | -20 °C to + 60 °C | |
| Operating humidity | Non-condensing (<10 °C) (< 50 °F) | |
| ≤90% RH (at 10 °C to 30 °C [50 °F to 86 °F]) | ||
| ≤75% RH (at 30 °C to 40 °C [86 °F to 104 °F]) | ||
| ≤45% RH (at 40 °C to 50 °C [104 °F to 122 °F]) | ||
| (non-condensing) | ||
| Working altitude | 2000 m (6561 feet) | |
| Storage altitude | 12,000 m (39,370 feet) | |
| reference temperature | 23 °C ±5 °C (73 °F ±9 °F) | |
| temperature coefficient | 0.15% x (specified accuracy) / °C (28 °C [82.4 °F]) | |
| Overload indication | OL | |
| Data logging capacity | Minimum 32,760 measured values | |
| Data logging interval | 1 second to 59 minutes and 59 seconds | |
| Displays standard loop resistance reading specifications | ||
| Input (Ω) | minimal | greatest |
| 0.474 | 0.417 | 0.531 |
| 0.5 | 0.443 | 0.558 |
| ="10" | 9.55 | 10.45 |
| ="100" | ="96" | ="104" |
| safety | ||
| common (use) | IEC/EN 61010-1: Level 2 contamination IEC/EN 61557-1 | |
| surveying | IEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V | |
| Current clamp meter for leakage current measurement | IEC/EN 61557-13: Class 2, ≤ 30 A/m | |
| earth resistance | IEC/EN 61557-5 | |
| Effectiveness of protective measures | IEC/EN 61557-16 | |
| Electromagnetic Compatibility (EMC) | international standard | IEC/EN 61326-1: Portable electromagnetic environments |
| CISPR 11: Group 1, Class B, IEC/EN 61326-2-2 | ||
| Korea (KCC) | Class A equipment (industrial broadcasting and communications equipment) | |
| United States (FCC) | 47 CFR 15 Subpart B. This product is considered tax-exempt equipment under Section 15.103. | |
| radio | ||
| frequency range | 2412 MHz to 2462 MHz | |
| output power | <10 mW | |
| Radio frequency certification | FCC ID:T68-FBLE IC:6627A-FBLE | |
| General technical indicators | ||
| Conductor Specifications | Approx. 40 mm (1.57 in) | |
| Dimensions (L x W x H) | 283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in) | |
| weights | 880g (31 oz) | |
| warranty period | 1 year | |
| Ground loop resistance | ||
| range (of scales or measuring equipment) | accurate ="1" ± (± % + Ω of reading) | |
| 0.025 Ω to 0.249 Ω | 1.5% + 0.02 Ω | |
| 0.250 Ω to 0.999 Ω | 1.5% + 0.05 Ω | |
| 1.000 Ω to 9.999 Ω | 1.5% + 0.10 Ω | |
| 10.00 Ω to 49.99 Ω | 1.5% + 0.30 Ω | |
| 50.00 Ω to 99.99 Ω | 1.5% + 0.50 Ω | |
| 100.0 Ω to 199.9 Ω | 3.0% + 1.0 Ω | |
| 200.0 Ω to 399.9 Ω | 5.0% + 5.0 Ω | |
| 400 Ω to 599 Ω | 10.0% + 10 Ω | |
| 600 Ω to 1500 Ω | 20.00% | |
| ="1" Loop resistance is non-inductive, conductors are centered and perpendicular to the jaws. | ||
| Ground leakage current measurement mA | ||
| Auto range 50/60 Hz, true RMS, crest factor CF ≤3 | ||
| range (of scales or measuring equipment) | resolution (of a photo) | accurate ="1" ± (± % + mA of reading) |
| 0.200 mA to 3.999 mA | 1 μA | 2.0% + 0.05 mA |
| 4.00 mA to 39.99 mA | 10 μA | 2.0% + 0.03 mA |
| 40.0 mA to 399.9 mA | 100 μA | 2.0% + 0.3 mA |
| 0.400 A to 3.999 A | 1 mA | 2.0% + 3 mA |
| 4.00 A to 39.99 A | 10 mA | 2.0% + 30 mA |
="1" Applicable signal frequency
|
||
Model: Fluke 1630-2/1630-2 FC Ground Loop Resistance Test Clamp Meter
FLUKE-1630-2 FC
- 1630-2 FC Ground Loop Resistance Test Clamp Meter
- Hard suitcase
- Standard Loop Resistance Calibration Board
- 4 AA batteries
- Safety Information Guide and Quick Reference Guide
Comprehensive test and measurement service provider-Shenzhen Weike Electronic Technology Co.