Fluke 1503 Insulation Resistance Tester
Fluke 1503 Insulation Resistance Tester
Fluke 1503 Insulation Resistance Tester
Fluke 1503 Insulation Resistance Tester
Fluke 1503 Insulation Resistance Tester
Fluke 1503 Insulation Resistance Tester

Fluke 1503 Insulation Resistance Tester

¥999,999.00

Main characteristics

  • Insulation test range: 1.5 mm
    • 0.1 MΩ to 2000 MΩ
  • Insulation Test Voltage: -40V
    • 500 V, 1000 V
  • Remote test probes facilitate repetitive testing and testing in inaccessible locations.
  • Real-time circuit detection feature prohibits insulation testing at voltages above 30 V, increasing the level of safety
  • Automatic discharge of capacitive voltages for better user protection
  • AC/DC voltage: 0.1 V to 600 V
  • 200 mA continuous current
  • Resistance: 0.01 Ω to 20.00 kΩ
  • Auto shut-off feature saves battery power
  • Large backlit display for easy reading of measurement results
  • CAT IV 600 V overvoltage category rating enhances the user's level of safety
  • Each tester comes with remote probe, test lead, probe and alligator clips
  • Fitting the optional Fluke TPAK magnetic suspension system frees up your hands for other tasks.
  • Four AA alkaline batteries (NEDA 15 A or IEC LR6) for a minimum of 1000 insulation tests
  • One Year Warranty

SKU:Fluke 1503 Category. Brand.

  
  • Quantity
    • -
    • +
  •    
Inquire about this product

Product Overview: Fluke 1503 Insulation Resistance Tester

The Fluke 1503 Insulation Testers are compact, rugged and very easy to operate. With the ability to accept a wide range of test voltages, they are the ideal tool for many overhaul, commissioning and preventive maintenance situations.

These tools are also equipped with other components such as remote probes, which makes the testing process very fast and cost effective.

Product Specification: Fluke 1503 Insulation Resistance Tester

AC/DC voltage measurement
accurate range (of scales or measuring equipment) 600.0 V
resolution (of a photo) 0.1 V
50 Hz to 400 Hz ± (% + bits of reading) ± (2% + 3)
Input Impedance 3 MΩ (nominal), < 100 pF
Common mode attenuation rate (1 kΩ unbalanced) > 60 dB at DC, 50 or 60 Hz
overload protection 600 V rms or DC
Measurement of earth connection resistance
Range/Resolution 20.00 Ω 0.01 Ω
200.0 Ω 0.1 Ω
2000 Ω 1.0 Ω
20.00 kΩ 0.01 kΩ
accurate ±(1.5% + 3)
overload protection 2 V rms or DC
Open Circuit Test Voltage > 4.0 V, < 8 V
short-circuit current > 200.0 mA
Insulation specifications
Measured value range 0.01 MΩ to 2000 MΩ
test voltage 500 V, 1000 V
Test Voltage Accuracy + 20%, - 0%
short-circuit current 1 mA (nominal)
Automatic discharge Discharge time < 0.5 sec, C = 1 µF or less
Live Circuit Indicator Inhibit test if termination voltage > 30 V before initialization test
Maximum capacitive load Operable with loads below 1 µF
Measurement accuracy
output voltage Display range resolution (of a photo) Test Current accuracy
± (% reading + lowest significant bit amount)
500 V (0 % to + 20 %) 0.1 to 20.0 MΩ 0.01 MΩ 1 mA @
500 kΩ
± (2.0 % + 5)
20.0 to 200.0 MΩ 0.1 MΩ
200 to 500 MΩ 1 MΩ
1000 V (0 % to + 20 %) 0.1 to 200.0 MΩ 0.1 MΩ 1 mA @
1 MΩ
± (2.0 % + 5)
200 to 2000 MΩ 1 MΩ
General technical indicators
Maximum voltage applied to any terminal: 600 V AC rms or DC
storage temperature -40 °C to 60 °C (-40 °F to 140 °F)
operating temperature -20 °C to 55 °C (-4 °F to 131 °F)
temperature coefficient 0.05 x (specified accuracy)/°C at temperatures 28 °C ( 82 °F)
relative humidity
0% to 95% at 10 °C to 30 °C (50 °F to 86 °F)
0% to 75% at 30 °C to 40 °C (86 °F to 104 °F)
0% to 40% at 40 °C to 55 °C (104 °F to 131 °F)
vibratory Random, 2 g, 5-500 Hz, according to MIL-PRF-28800F Class 2 Instruments
impingement 1 m drop according to IEC 61010-1 2nd edition (1 m drop test, six sides, oak floor)
electromagnetic compatibility Accuracy = specified accuracy in an RF magnetic field of 3 V/M (EN 61326-1:1997)
safety Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd edition, Class IV measurement 600 V (CAT IV).
accreditation CSA according to standard CSA/CAN C22.2 No. 61010.1-04; TUV according to standard IEC/EN 61010-1 2nd edition.
batteries Four AA batteries (NEDA 15A or IEC LR6)
Battery life Insulation testing purposes: At room temperature, the new alkaline batteries will allow the meter to perform at least 1000 insulation tests. These standard results are measured with 1000 V passed through a 1 MΩ resistor, with an operating cycle of 5 seconds on and 25 seconds off.
Resistance measurements: The new alkaline batteries allow the meter to make at least 2500 ground connection insulation measurements at room temperature. These standard results are measured at 1 Ω resistance with a 5 second on, 25 second off duty cycle.
Dimensions (H x W x D) 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
weights 550 g (1.2 lb)
IP Protection Rating IP40
height above sea level Working altitude 2000 m CAT IV 600 V, 3000 m CAT III 600 V
Non-operational (storage) 12000 m
overcapacity 110% Range
Includes accessories TL224 Test Lead, TP74 Test Probe, Clip Part Numbers 1958654 (Red) and 1958646 (Black), Holster and Remote Probe

Model: Fluke 1503 Insulation Resistance Tester

FLUKE- 1503

Insulation multimeter

Includes.

  • remote probe
  • Test Leads
  • Test Probes
  • spring clip
  • holster
  • user manual

F1503 Technical Data [Please login to download and view].