SHS1000X Series Handheld Oscilloscope
SHS1000X Series Handheld Oscilloscope
SHS1000X Series Handheld Oscilloscope
SHS1000X Series Handheld Oscilloscope
SHS1000X Series Handheld Oscilloscope
SHS1000X Series Handheld Oscilloscope
SHS1000X Series Handheld Oscilloscope
SHS1000X Series Handheld Oscilloscope
SHS1000X Series Handheld Oscilloscope
SHS1000X Series Handheld Oscilloscope
SHS1000X Series Handheld Oscilloscope
SHS1000X Series Handheld Oscilloscope

SHS1000X Series Handheld Oscilloscope

Price range: ¥10,680.00 through ¥18,980.00
  
  • Quantity
    • -
    • +
  •    
Inquire about this product
  • Isolation Voltage Class CAT II 1000 Vrms, CAT III 600 Vrms,
  • Integration of oscilloscope, multimeter, waveform recorder, measured value recorder, protocol analysis, FFT spectrum analyzer in one unit
  • Bandwidth 70 MHz, 100 MHz, 200 MHz, memory depth 12 Mpts, sample rate 1 GSa/s
  • SPO digital fluorescence technology with waveform refresh rate of 100,000 fps (up to 400,000 fps in Sequence mode)
  • Weighing only 1.75 kg, it comes standard with a portable shoulder bag that can easily hold a wide range of probes and accessories.
  • Hardware-based implementation of a true RMS multimeter
  • New Li-ion battery with 6900 mAh capacity and 4 hours of battery life
  • Dust and water resistant to IP51

Fully isolated design to CAT III measurement category

IEC61010-2-030 defines measurement categories that rate the ability of a measuring instrument to withstand short-term transient overvoltages in addition to the operating voltage. the SHS1000X can be tested up to 1000 Vrms and 600 Vrms under CATII and CAT III categories, respectively.
● CAT II:
Used to measure circuits that are connected directly to low voltage devices, such as household appliances or portable use tools, via standard sockets.
● CAT III.
Used for measurements installed in buildings, such as junction boxes, circuit breakers, distribution boards and equipment permanently connected to fixed installations.SHS1000X series oscilloscopes are isolated between the two channels, oscilloscope channel, multimeter channel, and USB interface, which protects the safety of the equipment under test, as well as the safety of personnel and data.

SHS1000X-01

Multiple decoding functions as standard

In the automotive and embedded industries, serial protocol buses are often required to be observed, and the SHS1000X comes standard with five types of serial protocol triggers and decoders: IIC, SPI, UART, CAN, and LIN. Due to its unique portable design and battery-powered, the SHS1000X is more than capable of meeting the test requirements of the automotive and embedded industries that require on-site decoding.
SHS1000X-02

IP51 rated dust and water resistant

The newly upgraded ruggedized case with good sealing design gives SHS1000X the ability to work properly in dusty, humid and other harsh environments. The clear feel of the physical buttons and the large dials provide a full sense of operation even with gloves.
SHS1000X-03

Hardware-based implementation of a true RMS multimeter

Multimeters are commonly used in field testing. The SHS1000X series integrates a 6000-count multimeter that supports DC voltage and current, AC voltage and current, resistance, capacitance, diode, and on/off function measurements, and realizes true RMS measurement. It greatly improves the efficiency of field testing.
SHS1000X-04

model numberbandwidthschannel numberMaximum real-time sampling rateStorage depthWaveform Refresh RateMultimeter FunctionsloggerReference price (including tax)
SHS1072X70 MHz21 GSa/s12 Mpts400,000 frames/sec (Sequence mode)Voltage, current, resistance, etc. Eight common functionsUp to 22 hours¥10,680
SHS1102X100 MHz21 GSa/s12 Mpts400,000 frames/sec (Sequence mode)Voltage, current, resistance, etc. Eight common functionsUp to 22 hours¥14,980
SHS1202X200 MHz21 GSa/s12 Mpts400,000 frames/sec (Sequence mode)Voltage, current, resistance, etc. Eight common functionsUp to 22 hours¥18,980

Specification
Oscilloscope sectionMultimeter section
model numberSHS1072XSHS1102XSHS1202Xresolution (of a photo)6000 Counts
bandwidths70 MHz100 MHz200 MHzDC Voltage Measurement60 mV±1%±15 digit
Maximum real-time sampling rateSingle 1 GSa/s ADC chip, 1 GSa/s sampling rate when channels are interleaved, 500 MSa/s sampling rate per channel when all channels are turned on600 mV-600 V±1%±5 digit
channel number2 Oscilloscope Channels, 1 Multimeter Interface1000V±1.5%±5digit
Maximum storage depthChannel interleaved mode 12 Mpts/CH, non-interleaved mode 6 Mpts/CHAC Voltage Measurement60 mV±1%±15 digit
Maximum waveform capture rate400,000 frames/sec (Sequence mode)600 mV-600 V±1%±5 digit
Trigger TypeEdge, Slope, Pulse width, Window, Runt, Interval, Dropout, Pattern, Video, Serial Trigger (IIC, SPI, UART, CAN, LIN)750V±1.5%±5digit
Decoding type (standard)IIC, SPI, UART, CAN, LINDC Current Measurement60 mA-600 mA±4%±10digit
loggerWaveform recorder with a maximum recording sample rate of 25 kSa/s and a minimum sample rate of 1Sa/s6 A-10 A±5%±5 digit
Measured value recorder with a maximum recording interval of 10 minutes and a minimum recording interval of 0.1 seconds. Up to 4 groups can be recorded simultaneouslyAC Current Measurement60 mA-600 mA±4%±10digit
connectorUSB Host, USB Device6 A-10 A±5%±5 digit
Maximum safe input voltage (oscilloscope)BNC between signal terminal and protective earth CAT III 600 Vrms, CAT II 1000 VrmsCapacitance Measurement40 nF±5%±50 digit
BNC between ground terminal and protective earth CAT III 600 Vrms, CAT II 1000 Vrms400 nF-400 μF±5%±5 digit
CAT III 300 Vrms between BNC signal terminal and BNC ground terminalResistance Measurement600 Ω-6 MΩ±1%±5 digit
Maximum safe input voltage (multimeter)CAT III 600 Vrms, CAT II 1000 Vrms60 MΩ±4%±5 digit
extend one's head (out or into)PB925PB925PB925conductionresistive Buzzer sounds when < 50 Ω
monitor5.6-inch TFT-LCD display with 640 * 480 resolutionDiode Testing0-2 V
weightsNet weight 1.75 kg, gross weight 3.5 kg
General Characteristics
interface display5.6-inch TFT-LCD display with 640 * 480 resolution
Power supply methodNative battery-powered or external DC adapter power supply, built-in power supply lithium battery: 6900 mAh Battery power for about 4 hours External adapter: 100-240 V 50/60 Hz input 9 V, 4 A output
body size276 mm * 168 mm * 68 mm
replacement (parts)Two passive probes, power cord, DC adapter, multimeter pen

SHS1000X series datasheet [please login to download and view]

SHS1000X Series User's Manual [Please login to download and view].

SHS1000X Series Programming Manual [please login to download and view]

SHS1000X Series Quick Guide [Please login to download and view]

SHS800X Open Source Acknowledgment[Please login to download and view].

GSCH4000A Intelligent Battery Charging Cradle Instruction Manual [Please login to download and view].

Probe datasheet [Please login to download and view].

List of passive probes that come standard with oscilloscopes [please login to download and view]

Time Domain Full Series Product Brochure [Please login to download and view].

Selection guide for the whole series of products [Please login to download and view].

 

Expand More
SHS1000X Series Handheld OscilloscopeSHS1000X Series Handheld Oscilloscope
Price range: ¥10,680.00 through ¥18,980.00
Purchase of goods

Product consultation and purchase:18218718851

I already understand