TH9130 series multifunctional safety comprehensive analyzer is designed for the full performance safety testing of electronic and electrical equipment. Including AC/DC withstand voltage, insulation resistance, grounding resistance, conduction test, electrical performance and leakage current and other safety test functions.

Categories. , Tags. , Brand.

Inquire about this product
  • TH9130S/TH9131S Series Multi-Channel High Power Withstand Voltage and Ground Tester is designed for full performance safety testing of electronic and electrical equipment. It can scan multi-channel including AC/DC withstand voltage, insulation resistance, grounding resistance and other safety test functions.

Withstand Voltage Test: Output power AC:500VA/200VA (5kV/100mA, 5kV/40mA), DC:120VA (6kV/20mA), so it can be used to do the withstand voltage test for high-power electrical appliances, motors and other aspects of the equipment, and also can do the same test on the parts.

Insulation resistance test: display range 0.1MΩ-50GΩ, test voltage 50V-6000V arbitrary settings.

Ground resistance test: current up to 40A, and test voltage can be set. It can also be carried out at the same time with the withstand voltage test, which greatly shortens the test time and improves the test efficiency.

The instrument is equipped with a 7-inch touch screen, which allows direct touch control of the instrument, with all test modes, times, voltages, currents, resistance values, and test steps displayed on the same screen. All test modes, time, voltage, current, resistance value and test steps are displayed on the same screen. There is also a list display mode, which shows multi-step settings and sequential test results.

The instrument is equipped with RS-232C, USB, HANDLER, and optional GPIB, which make the instrument adaptable to a variety of different needs for high security and reliability of automatic test systems.

TH9130S/TH9131S series multi-channel high power withstand voltage grounding testers include the following types:

model number TH9130S TH9131S
scanning module TH9130S-004 TH9130S-001 TH9130S-002 TH9130S-003 TH9130S-004 TH9130S-001 TH9130S-002 TH9130S-003
oppressive ACW 5.0kV/100mA/500VA 5.0kV/40mA/200VA
DCW 6.0kV/20mA/120VA
IR Voltage: 6.0kV; Resistance: 50.0GΩ
conduit 4 8 8 S 4 8 8 S
CK contact check R R R S R R R S
GB realm Current: 40.00A (AC); Voltage: 3.00-8.00V; Resistance: 0-600mΩ
conduit 4 8 S 8 4 8 S 8
linear four-line second-tier S four-line four-line second-tier S four-line
conduction R R R R R R R R

appliance

  • Comprehensive electrical performance test analysis of household electrical
  • Comprehensive test analysis of lighting appliances
  • Comprehensive motor analysis test
  • High Power Appliance Testing and Analysis
  • Comprehensive test analysis of electronic parts

Technical Parameters

A. 7-inch capacitive touch screen, 800 x 480 resolution

TH9130S/TH9131S series multi-channel high power withstand voltage grounding tester adopts 7-inch 800*480 resolution capacitive touch screen, Linux system safety test instrument, its touch operation, interactive operation experience, greatly shorten the time of the instrument setup and operation, and improve the efficiency.

1691210830991624

Setup interface: set all parameters on the same page

1691210934124361

B. Five-in-one, multi-channel integrated test, a single machine to achieve all the safety test needs

TH9130S/TH9131S Series Multi-Channel High Power Withstand Voltage Ground Tester integrates five safety test functions

functionality Basic parameters instructions
AC withstand voltage

ACW

input voltage 0.05-5.0kV High power output, suitable for testing appliances with motors such as refrigerators, air conditioners, washing machines, etc.

High power transformer, high power motor testing

amps 0.001mA-100mA (Voltage > 4kV)

0.001mA-120mA (Voltage ≤ 4kV)

power (output) 500VA
DC withstand voltage

DCW

input voltage 0.05-6.0kV Automatic discharge at the end of the test to protect human safety
amps 0.0001mA-20mA (Voltage <1.5kV)

0.0001mA-25mA (Voltage ≤ 1.5kV)

power (output) 150VA
electrical insulation resistance

IR

input voltage 0.05-6.0kV Output voltage exceeds that of most insulation testers on the market

1kV

resistive 0.1MΩ- 50.0GΩ
earth resistance

GB

amps 1.00-40.00A (AC) Meets most grounding resistance testing requirements

Simultaneous testing with voltage withstand to improve testing efficiency

input voltage 3.00-8.00V
numerical value of electrical impedance 0-600mΩ
conduction amps 0.0001A-0.1A
resistive 0.00-10.000kΩ

C. Simultaneous voltage withstand/grounding tests for improved efficiency

TH9130S/TH9131S series multi-channel comprehensive safety analyzer built-in bi-amplifier technology, synchronous output of high voltage and high current, support voltage withstand and grounding synchronous test, greatly reducing the production line test time.

1691211672476447

D. Electric shock protection function to protect the safety of testers

1691211901125394-1

When the operator is electrocuted, the ammeter measures different values, and the current I3= i2-i1, when i3 is too high, it is judged to be electrocution, and the output will be cut off immediately to protect the safety of users.

 

 

model number TH9130S TH9131S
scanning module TH9130S-004 TH9130S-001 TH9130S-002 TH9130S-003 TH9130S-004 TH9130S-001 TH9130S-002 TH9130S-003
Functions & Channels High voltage: ACW, DCW, IR 4 8 8 S 4 8 8 S
CK contact check R R R S R R R S
Ground resistance (GB) conduit 4 8 S 8 4 8 S 8
linear four-line second-tier S four-line four-line second-tier S four-line
conduction R R R R R R R R
Pressure resistance test
output voltage AC realm 0.05 - 5.0kV
waveform 50/60Hz±0.1% sine wave
output power 500VA (5.0kV/100mA) 200VA
DC realm 0.05 - 6.0kV
output power 150VA (6.0kV/25mA) 120VA
Load variability ± (1% setting + 10V) (rated power)
resolution (of a photo) 2V
accurate ± (1% setpoint +5V)
current test AC realm V≤4kV 0.001mA - 120mA 0.001mA -40mA
V>4kV 0.001mA - 100mA 0.001mA -40mA
resolution (of a photo) 0.001mA
accurate 120mA 0.1mA-120.0mA ± (1% reading + 0.6mA)
30mA 0.01mA-29.99mA ± (1% reading + 0.15mA)
3mA 0.001mA-2.999mA ± (1% reading + 0.015mA)
DC realm V≥1.5kV 0.0001mA - 25mA 0.0001mA - 20mA
V<1.5kV 0.0001mA - 20mA 0.0001mA - 20mA
resolution (of a photo) 0.1μA
accurate 25mA 0.01mA - 25.00mA ± (1% reading + 0.12mA)
3mA 0.001mA - 2.999mA ± (1% reading + 0.015mA)
5.1μA 0.1μA-299.9μA ± (1% reading + 1.5 μA)
time setting Testing time 0.3 - 999s, 0 for continuous testing
rising time 0.1 - 999s, 0 for off
descent time 0.1 - 999s, 0 for off
waiting time 0.1 - 999s, 0 for off (DC withstand voltage only)
arc detection AC 1.0mA - 20.0mA 1.0mA - 20.0mA
DC 1.0mA - 10.0mA
Maximum short-circuit current (AC test only) 200mA 80mA
Rapid Discharge Function Automatic discharge at the end of the test (DCW)
Insulation resistance test
input voltage exports DC:0.05 - 6.0kV
resolution (of a photo) 2V
accurate ± (1% reading +5V)
resistive Test Range 0.1MΩ - 50.0GΩ
Test Accuracy V≥1kV 1MΩ - 1GΩ ± (3% reading + 1M)
1GΩ - 10GΩ ± (7% reading + 0.2G)
10GΩ - 50GΩ ± (10% reading + 0.5G)
500V≤V<1kV 0.1MΩ - 1GΩ ± (3% reading + 1M)
1GΩ - 10GΩ ± (7% reading + 0.2G)
10GΩ - 50GΩ ± (10% reading + 0.5G)
V<500V 1MΩ - 1GΩ ± (5% reading + 100V/Vs*10M)
time setting Testing time 0.3 - 999s, 0 for continuous testing
rising time 0.1 - 999s, 0 for off
descent time 0.1 - 999s, 0 for off
waiting time 0.1 - 999s, 0 for off
Rapid Discharge Function Automatic discharge at the end of the test
AC Ground Resistance Testing
Output Current realm 1.00 - 40.00A
resolution (of a photo) 0.01A
accurate ± (2% setpoint + 2 words)
test voltage realm 3.00 - 8.00V
resolution (of a photo) 0.01V
accurate ± (2% setpoint + 3 words)
Test Frequency 50/60Hz±0.1%
Output Adjustment Rate ± (1% output value + 0.02A)
Resistance Testing realm 1.00 - 10.00A 0 - 600mΩ
10.01 - 30.00A 0 - 200mΩ
30.01 - 40.00A 0 - 150mΩ
accurate 1.00 - 3.00A 0 - 600mΩ ± (3% reading + 3 words)
3.01 - 10.00A 0 - 600mΩ ± (2% reading + 2 words)
10.01 - 30.00A 0 - 200mΩ ± (2% reading + 2 words)
30.01 - 40.00A 0 - 150mΩ ± (2% reading + 2 words)
Testing time 0.5 - 999s, 0 for continuous testing
Conductivity Test
Test Current 0.1A 0.00 - 10.00Ω
0.01A 10.1 - 100.0Ω
0.001A 101 - 1000Ω
0.0001A 1001 - 10000Ω
Resistance Test Accuracy 0 - 1000Ω ± (1% reading + 3 words)
1001 - 10000Ω ± (1% reading + 10 words)
Testing time 0.3 - 999s, 0 for continuous testing
OSC open/short circuit detection
Sampling standard capacitance range 0.001 - 40nF
Open Circuit Judgment Range 10% - 100%
Short Circuit Judgment Range 100% - 500%
Safety and security features
electrocution protection 0.5mA±0.25mA selectable: on or off
Startup Protection Interlock High-voltage output is allowed only when the pin is connected low
Panel operation protection key lock
warning indication Pass: short tone, green light; Fail: long tone, red light
Synchronized output test for withstand voltage and grounding 5kVac/30mAac and 30Aac/150mΩ
Storage and Interfaces
internal memory Up to 100 files can be stored and each file can be edited with 50 steps
Standard Interface RS232, USB DEVICE, USB HOST, LAN, HANDLER
Optional Interfaces GPIB
Ambient temperature and humidity
Parameter comparison temperature 18℃ - 28℃, Humidity:30% - 70%RH
normal working temperature 0°C - 45°C, Humidity:20% - 90%RH
Storage ambient temperature -10℃- 55℃, Humidity:<80%RH
General indicators
power supply 100V - 240VAC, 47Hz - 63Hz
power (output) No-load:<100W, rated power:1200W
Volume (W) x (H) x (D) 430mm×132mm×550mm
weights
  • Five-in-one integrated test system, a single machine to achieve all the safety test needs:

1) High Power AC Withstand Voltage Test

2) DC withstand voltage test

3) Insulation resistance test

4) Ground resistance test

5) Conductivity Test

  • Four/eight channel outputs
  • 500VA/200VA power AC withstand voltage design
  • Insulation resistance test up to 6kV
  • Hardware contact check (CK) function
  • Open short circuit detection OSC
  • Arc Detection ARC Function
  • Crash voltage test function
  • 7-inch capacitive touch screen, 800 x 480 resolution
  • Linux operating system, Chinese and English interface
  • Single-screen display of test mode, time, voltage, current, resistance value, test steps
  • List display function: Simultaneous display of test results of multi-step setup and sequential execution
  • Storage: 100 files, 50 steps/file

■ Comprehensive electrical performance test analysis of household electrical

■ Comprehensive motor analysis tests

■ Comprehensive test analysis of lighting appliances

■ High-power appliance test analysis

■ Comprehensive test analysis of electronic parts

■ Comprehensive test analysis of medical electrics

Expand More
TH9131S Multi-Channel High Power Withstand Voltage Ground TesterTH9131S Multi-Channel High Power Withstand Voltage Ground Tester

Click to enquire

Product consultation and purchase:18218718851

I already understand