TH2848-02 Precision Impedance Analyzer
TH2848-02 Precision Impedance Analyzer
TH2848-02 Precision Impedance Analyzer
TH2848-02 Precision Impedance Analyzer
TH2848-02 Precision Impedance Analyzer
TH2848-02 Precision Impedance Analyzer
TH2848-02 Precision Impedance Analyzer
TH2848-02 Precision Impedance Analyzer

TH2848-02 Precision Impedance Analyzer

TH2848 series precision impedance analyzers are designed for frequencies ranging from 4Hz-2MHz/5MHz/10MHz, with piezoelectric conductivity circle and dielectric constant test functions as standard, allowing impedance analysis functions to be further enhanced.

Categories. , Tags. , , Brand.

Inquire about this product

TH2848 series precision impedance analyzer is a new generation of precision impedance analyzer successfully developed by Tonghui Electronics by adopting the current international advanced auto-balance bridge principle and new generation of measurement and control technology, innovatively adopting the new generation of technology such as dual-CPU architecture, Linux underlying system, 10.1-inch capacitive touch-screen, Chinese and English operation interface, built-in instructions and help, etc., which solves the defects such as slow LCR test speed, single display, cumbersome operation and so on. LCR test speed is slow, single display, cumbersome operation and other defects.

TH2848 series precision impedance analyzers are designed for frequencies ranging from 4Hz-2MHz/5MHz/10MHz, with piezoelectric conductivity circle and dielectric constant test functions as standard, allowing impedance analysis functions to be further enhanced.

Thanks to the 10.1-inch capacitive touch screen with a resolution of 1280*800, the TH2848 series precision impedance analyzers have a four-parameter display, and all settings, monitoring, sorting parameters, and statuses can be displayed on the same screen, avoiding the tedious operation of frequent switching.

Quick Selection

Summary parameters TH2848-02L TH2848-02 TH2848-05 TH2848-10
Test Frequency 4Hz-2MHz 4Hz-2MHz 4Hz-5MHz 4Hz-10MHz
Basic precision 0.05%
ACsignal source input voltage 5mVrms - 2Vrms 5mVrms - 20Vrms
amps 0mArms - 20mArms 0mArms - 100mArms
DCbias voltage input voltage 0V - ±10V 0V - ±40V
amps 0mA - ±100mA 0mA - ±100mA
Independent Voltage Source 0V - ±10V
DCRtest signal input voltage 100mV-1V
amps 0mA - 10mA
Multi-function parameter list scanning R R R R
Graphical Analysis Scanning Graphic Scanning R R R R
piezoelectric conducting circle S R R R
dielectric constant S R R R

appliance

Passive components:

Evaluation of impedance parameters and performance analysis of capacitors, inductors, cores, resistors, piezoelectric devices, transformers, chip assemblies, and network components.

Semiconductor Components:

Test and analysis of parasitic parameters of LED driver integrated circuits; C-VDC characteristics of varactor diodes; analysis of parasitic parameters of transistors or integrated circuits

Other components:

Impedance evaluation of printed circuit boards, relays, switches, cables, batteries, etc.

Medium Material:

Evaluation of dielectric constants and loss angles of plastics, ceramics and other materials

Magnetic material:

Evaluation of permeability and loss angle of ferrites, amorphous and other magnetic materials

Semiconductor materials:

Dielectric constant, electrical conductivity and C-V properties of semiconductor materials

Liquid crystal materials:

C-V characteristics such as dielectric constant and elasticity constant of liquid crystal units

Piezoelectric materials and devices:

Piezoelectric ceramic filters, piezoelectric ceramic traps, piezoelectric ceramic discriminators, piezoelectric ceramic transformers, high-power ultrasonic generators, transducers (oscillators), surface acoustic wave devices, electro-acoustic devices, etc. can be tested, such as static capacitance, loss, resonance frequency, anti-resonance frequency, mechanical coupling coefficient and other parameters.

Technical Parameters

Functional Features

  1. highly accurate

TH2848 series precision impedance analyzer adopts wideband auto zero type auto balanced bridge technology, which can guarantee higher frequency accuracy in a wider frequency range compared with ordinary op-amp I/V type auto balanced bridge! The following figure takes Tonghui bridge as an example to compare the accuracy difference between auto-balanced bridge and ordinary bridge in the frequency range of 0-10MHz. Currently, Tonghui's wideband auto zeroing type auto balancing bridges include TH2839 series, TH2838 series and TH2828 series.

 

  1. High stability and consistency

TH2848 series precision impedance analyzer, in addition to the broadband automatic zero type auto-balance bridge principle brings high accuracy and high stability, the instrument built-in 15 test ranges, is also a strong guarantee of stability and consistency.

 

  1. 10.1Large inch screen with four measurement parameters for details at a glance

10.1-inch touch screen, 1280*800 resolution, Linux system, Chinese and English operation interface, support for keyboard, mouse, LAN interface, brings unparalleled ease of operation.

The large screen brings more benefits is that you can place four test parameters and sorting parameters, sorting results, function selection and other parameters in the same screen, and it never looks crowded and cluttered, and at the same time, you can display four kinds of measurement parameters, four kinds of measurement parameters can be adjusted arbitrarily.

The ease of operation and completeness of the display are readily apparent when compared to earlier LCRs.

  1. Piezoelectric device analysis function

For other piezoelectric devices such as piezoelectric ceramic filters, piezoelectric ceramic traps, piezoelectric ceramic frequency discriminator, piezoelectric ceramic transformers, high-power ultrasonic generators, transducers (oscillators), surface acoustic wave devices, electroacoustic devices and so on can be tested, such as static capacitance, loss, resonance frequency, anti-resonance frequency, mechanical coupling coefficient and other parameters.

For piezoelectric conductivity circle test that requires professionalism, the TH2848 series precision impedance analyzer is also built-in, without the need to purchase a host computer can be realized directly in the instrument graphical scanning analysis interface.

 

 

  1. Dielectric constant analysis function

In the field of material analysis, dielectric constant analysis is a basic content, TH2848 series precision impedance analyzer built-in dielectric test function, dielectric constant can be treated as a regular impedance analyzer test items like single test, list scanning, graphical scanning analysis.

 

  1. Enhanced multifunctional parameter list scanning

Supports up to 201 points of list scanning, each scanning point can be set to 4 measurement parameters, 4 measurement parameters have independent switches, list scanning each point of frequency, level, bias, function, delay can be set independently to meet the needs of most customers.

Improved list scanning sorting results output: each line can specify a different output, or any number of lines combined results output, all results can be directly output in the HANDLE interface

 

  1. Powerful graphical interface for analysis

4 scanning tracks, 1-4 test parameters can be selected arbitrarily, the scanning curve can be one screen, two screens, four screens

 

  1. 10Gear sorting and programmable HANDLER interface

The instrument provides 10 grades of sorting, which provides the possibility of grading the quality of the customer's products, and the sorting results are directly outputted to the HANDLER interface.

 

When connecting with automation equipment, how to configure the HANDLER interface output has always been a difficult problem for automation customers. TH2848 series precision impedance analyzers visualize the HANDLER interface pin position, input/output mode, corresponding signal, and answering mode completely, which makes automation connection simpler.

 

  1. Intelligent Firmware Upgrade Method

The instrument itself can be updated by upgrading the firmware without returning to the factory for function improvement, bug solution, function upgrade, and so on.

TH2848 series precision impedance analyzer firmware upgrade is very intelligent, can be carried out through the system setup interface or file management interface, intelligent search for the instrument memory, external USB flash drive or even LAN upgrade package, and automatically upgrade.

 

  1. Large memory, support for more profiles and image storage

The TH2848 series is upgraded with more memory, excluding the system footprint, users can use nearly 6GB of space to store more setup files and screenshots.

It also supports external USB storage expansion. The external USB storage supports setup files, screen shots, and data logging files.

Data log files are stored in external storage by default.

  1. K.Full Interface Configuration, No More Worries About Connectivity

The TH2848 comes standard with all common interfaces for communication with test instruments, making communication with computers and PLCs trouble-free.

 

  1. Standard Accessories

 

  1. Optional Test Accessories

 

Product Model TH2848-02L TH2848-02 TH2848-05 TH2848-10
demonstrate monitor (computer) 10.1-inch (diagonal) capacitive touch screen
proportions 16:9
resolution (of a photo) 1280×RGB×800
measured parameter way (of life) Four parameters can be selected arbitrarily
AC Cp, Cs, Lp, Ls, Rp, Rs, |Z|, |Y|, R, X, G, B, θ, D, Q, VACIAC
DC RDC
piezoelectricity (physics) Cp, D, ε, |ε|, εr', εr'', tanδ, Q
Test Frequency realm 4Hz-2MHz 4Hz-2MHz 4Hz-5MHz 4Hz-10MHz
accurate 0.01%
resolution (of a photo) 0.1mHz 20.0000Hz-99.9999Hz
1mHz 100.000Hz-999.999Hz
10mHz 1.00000kHz-9.99999kHz
100mHz 10.0000kHz-99.9999kHz
1Hz 100.000kHz-999.999kHz
10Hz 1.00000MHz-9.99999MHz
AC Test Signal Mode Rated value (ALC OFF) The set voltage is the Hcur voltage when the test terminal is open circuit
The set current is the current from Hcur when the test terminal is short-circuited.
Constant value (ALC ON) Keep the voltage on the DUT the same as the set value
Keep the current on the DUT the same as the set value
test level voltage range 0Vrms - 2Vrms 0mVrms-20Vrms F≤1MHz
0mVrms-15Vrms F>1MHz
0mVrms-2Vrms 2MHz<F≤5MHz
0mVrms-1Vrms 5MHz<F≤10MHz
accuracy ± (10% x setpoint + 2mV) (AC ≤ 2Vrms)

± (10% x setpoint + 5mV) (AC > 2Vrms)

resolution (of a photo) 0.1mVrms 0mVrms-0.2Vrms
0.2mVrms 0.2Vrms-0.5Vrms
0.5mVrms 0.5Vrms-1Vrms
1mVrms 1Vrms-10Vrms
10mVrms 10Vrms-20Vrms
current range 0mArms-20mArms 0mArms-100mArms
resolution (of a photo)

(100Ω internal resistance)

1μArms 0μArms-2mArms
2μArms 2mArms-5mArms
5μArms 5mArms-10mArms
10μArms 10mArms-100mArms
RDCbeta (software) voltage range 100mV-1V
resolution (of a photo) 100μV
current range 0mA-10mA
resolution (of a photo) 10μA
DC Bias voltage range 0V-±10V 0V-±40V
accuracy 1% x set voltage +5mV AC≤2V
2% x set voltage +8mV AC>2V
resolution (of a photo) 0.1mV 0V - ±5V
1mV ±5V - ±40V
current range 0mA - ±100mA
resolution (of a photo) 1μA 0mA-50mA
10μA 50mA-100mA
voltage source   voltage range -10V - 10V
  resolution (of a photo) 1mV
current range -45mA - +45mA
Output Impedance 100Ω
Test Side Configuration four-pronged attack (e.g. marriage)
Test cable length 0m, 1m
Output Impedance 100Ω, ±1%@1kHz
mathematical operation Absolute deviation from nominal value Δ, percentage deviation from nominal value Δ%
equivalence mode Series, parallel
calibration function Open OPEN, Short SHORT, Load LOAD
Measured average 1-255 times
Range Selection Auto AUTO, Manual HOLD
Trigger Mode Continuous, single
Trigger delay 0-60s
Exclusive Features One-click screenshot, one-click recording, embedded help system
Range Configuration LCR 100mΩ, 1Ω, 10Ω, 20Ω, 50Ω, 100Ω, 200Ω, 500Ω, 1kΩ, 2kΩ, 5kΩ, 10kΩ, 20kΩ, 50kΩ, 100kΩ
RDC 10Ω, 20Ω, 50Ω, 100Ω, 200Ω, 500Ω, 1kΩ, 2kΩ, 5kΩ, 10kΩ, 20kΩ, 50kΩ, 100kΩ
Measurement time (ms/time) Fast: 2.5ms,

Medium speed: 90ms

Slow: 220ms

Maximum accuracy 0.05% (refer to specifications)
Measurement display range a: 1 x 10-18(b); E: 1 x 1018
Cs, Cp 0.00001pF - 9.99999F
Ls, Lp 0.00001μH - 99.9999kH
D 0.00001 - 9.99999
Q 0.00001 - 99999.9
r, rs, rp, x, z, rDC 0.001mΩ - 99.9999MΩ
G, B, Y 0.00001μs - 99.9999S
VDC ±0V - ±999.9999V
IDC ±0A - ±999.9999A
θr -3.14159 -   3.14159
θd -179.999° - 179.999°
Δ% ± (0.000% - 999.9%)
Multi-function parameter list scanning check numbers 201 points, average can be set for each point, each point can be sorted individually
parameters Test frequency, AC voltage, AC current, DC BIAS voltage, DC BIAS current, and test function with dielectric constant are realized based on the parameter settings of each point in this list.
Trigger Mode Sequential SEQ: When triggered once, measurements are taken at all scan points, /EOM/INDEX is output only once
Step STEP: Performs one scan point measurement per trigger and outputs /EOM/INDEX at each point, but list scan comparator results are only output at the last /EOM
Other features 1. Multiple copy functions for both scanning and testing parameters

2. Time delay can be set for each scanning point.

comparator Each scanning point can measure up to four test parameters, each parameter can be set upper and lower limits, all test parameters are qualified to output PASS signal, otherwise output FAIL signal, not set upper and lower limits are not judged
Graphic Scanning Scanning Points Points 51, 101, 201, 401, 801 are optional
The results show that Extreme values for each parameter and the scanned parameter value at the point where the cursor is located with the corresponding test parameter value
Piezoelectric test Integrated Piezoelectric Conductivity Circle Test Solution
scanning track 1-4 test parameters can be selected arbitrarily, and the scanning curve can be divided into one screen, two screens and four screens.
Display range Real-time automatic, locked
coordinate scale Logarithmic, linear
scanning parameter Frequency, AC Voltage, AC Current, DCV BIAS/DCI BIAS
trigger method one-off Trigger manually once, one scan from start to finish is completed, the next trigger signal starts a new scan
progression Infinite loop scanning from start to finish
Results Saving Graphics, documentation
comparator Bin Staging 10Bin, PASS, FAIL
Bin deviation setting Deviation value, percent deviation value, off
Bin mode Tolerance, continuous
Bin Count 0-99999
grade differentiation Each file can set up to four parameter limit range, four test parameter results within the set file display corresponding file number, beyond the set maximum file number range will display FAIL, not set the upper and lower limits of the test parameters are automatically ignored file discrimination
PASS/FAIL indication If Bin1-10 is met, the front panel PASS light is on, otherwise the FAIL light is on.
data cache 201 measurements can be read in batches
store a call (computing) inside (part, section) The instrument has 8GB of built-in storage space, after removing the system occupied by the user can use the space of about 6GB
External USB Test setup files, screenshot graphics, log files
Keyboard Lock Lockable front panel keys
connector USB HOST 2 USB HOST ports, can be connected to the mouse, keyboard, U disk at the same time can only use a
USB DEVICE Universal Serial Bus socket, small Class B (4 contact positions); compliant with USB TMC-USB 488 and USB 2.0, female connector for connection to external controller.
LAN 10/100M Ethernet, 8-pin, two speeds adaptive
HANDLER For Bin Staging Signal Output
GPIB standard equipment
RS232C Standard 9-pin, Crossed
RS485 standard equipment
Power-on warm-up time 60 minutes.
Input Voltage 100-120VAC/198-242VAC selectable, 47-63Hz
power wastage Not less than 130VA
Dimensions (WxHxD) mm 430x177x265
weights 11kg

- Test frequency: 4Hz-2MHz

- High precision 0.05%: Adopting auto-balanced bridge technology, four-end pair test configuration

- High resolution: 10.1-inch, 1280*800 resolution, capacitive touch screen

- High stability and consistency: 15 range configurations

- High power: Signal level: 20VAC/100mAAC

Built-in DC bias: ±40VDC/100mADC

- High speed: dual CPU architecture, the fastest test speed up to 400 times / s (2.5ms)

- Convenient operation: Linux operation base layer, touch operation, embedded help

- Three types of tests: point test, list scan, and graphic scan

- Four-parameter measurement

- One-click recording, one-click screenshot

- 201-point multi-parameter list scanning function

- Graphic scanning function, 4 tracks optional, support 1/2/4 split screen

- Piezoelectric Conductivity Circle Test, Dielectric Constant Test

- Powerful sorting: LCR mode: 10-speed sorting

Graphical analysis mode: supports curve condition sorting

- High compatibility: supports SCPI/MODBUS command set, compatible with KEYSIGHTE4980A, E4980AL, HP4284A

Passive components:

Evaluation of impedance parameters and performance analysis of capacitors, inductors, cores, resistors, piezoelectric devices, transformers, chip assemblies, and network components.

Semiconductor Components:

Test and analysis of parasitic parameters of LED driver integrated circuits; C-VDC characteristics of varactor diodes; analysis of parasitic parameters of transistors or integrated circuits

Other components:

Impedance evaluation of printed circuit boards, relays, switches, cables, batteries, etc.

Medium Material:

Evaluation of dielectric constants and loss angles of plastics, ceramics and other materials

Magnetic material:

Evaluation of permeability and loss angle of ferrites, amorphous and other magnetic materials

Semiconductor materials:

Dielectric constant, electrical conductivity and C-V properties of semiconductor materials

Liquid crystal materials:

C-V characteristics such as dielectric constant and elasticity constant of liquid crystal units

Piezoelectric materials and devices:

Piezoelectric ceramic filters, piezoelectric ceramic traps, piezoelectric ceramic discriminators, piezoelectric ceramic transformers, high-power ultrasonic generators, transducers (oscillators), surface acoustic wave devices, electro-acoustic devices, etc. can be tested, such as static capacitance, loss, resonance frequency, anti-resonance frequency, mechanical coupling coefficient and other parameters.

standard equipment
Accessory Name model number
Boxed Four-Ended Insulated Locking Kelvin Test Leads TH26011BS
fixture (machining) TH26048
short circuit board TH26010
optional
Accessory Name model number
Dielectric Test Fixture TH26077
High Frequency Patch Fixture TH26108C
Magnetic Ring Fixture TH26008A
Magnetic Ring Clamp (Piece Type) TH26007A
Patch Test Leads with Boxes TH26009B
fixture (machining) TH26047
Test Fixture TH26062
Test Fixture TH26063
Expand More
TH2848-02 Precision Impedance AnalyzerTH2848-02 Precision Impedance Analyzer

Click to enquire

Product consultation and purchase:18218718851

I already understand